Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
Whey, lactose-low
EC Number:
295-893-9
EC Name:
Whey, lactose-low
Cas Number:
92129-93-6
IUPAC Name:
Whey, lactose-low

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
> 600 °C
Atm. press.:
985 hPa
Remarks on result:
other: As no auto-ignition temperature was obtained up to 600°C, the final auto-ignition temperature is above 600°C.

Any other information on results incl. tables

Three trials were conducted. In the first one, the preselected auto-ignition temperature was set to 150°C but no ignition occurred and the test stopped automatically. In the second one, the preselected auto-ignition temperature was set to 350°C but no ignition occurred and the test stopped automatically. In the third one, the preselected auto-ignition temperature was set to 550°C but no ignition occurred and the test stopped automatically.

As no auto-ignition temperature was obtained up to 600°C, the final auto-ignition temperature is above 600°C.

The atmospheric pressure was 986.0 hPa at the beginning of the test and 984.0 hPa at the end of the test.

Applicant's summary and conclusion

Conclusions: