Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
January 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Qualifier:
according to guideline
Guideline:
other: ASTM Standard E-680-79
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Purity: 99.3%
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not thermal sensitive if heated under defined confinement
Key result
Test series:
UN Test series 1
Method:
UN Test 1 (b): Koenen test
Parameter:
limiting diameter (mm)
Remarks on result:
no ignition, explosion, self-heating or visible decomposition
Key result
Test series:
UN Test series 1
Method:
UN Test 1 (a): UN gap test
Parameter:
limiting impact energy (J)
Remarks on result:
no ignition, explosion, self-heating or visible decomposition

Test of Thermal Sensitivity: No explosions were observed for the test substance for tests conducted with either the

6-mm or 2-mm diameter orifice plates.

Test of Mechanical Sensitivity with Respect to Shock: No positive results were obtained for the test substance in 21 successive drop impact tests conducted at 48 Joules (3.5 kg at 1.40 m).

Interpretation of results:
GHS criteria not met
Conclusions:
The test substance was not found to be sensitive to thermal, friction, or impact stimuli.

Description of key information

The test substance was not found to be sensitive to thermal, friction, or impact stimuli.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

Test of Thermal Sensitivity: No explosions were observed for the test substance for tests conducted with either the

6-mm or 2-mm diameter orifice plates.

Test of Mechanical Sensitivity with Respect to Shock: No positive results were obtained for the test substance in 21 successive drop impact tests conducted at 48 Joules (3.5 kg at 1.40 m).