Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012-09-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Version / remarks:
, 1981
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7520 (Particle Size, Fiber Length, and Diameter Distribution)
Version / remarks:
, 1996
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ISO 13320: Particle size analysis – Laser diffraction methods
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D50
Mean:
27 µm
Remarks on result:
other: mean of six measurements(migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.)
Percentile:
D10
Mean:
4.99 µm
St. dev.:
0.16
Remarks on result:
other: mean of six measurements
Percentile:
D50
Mean:
26.75 µm
St. dev.:
2.09
Remarks on result:
other: mean of six measurements
Percentile:
D90
Mean:
82.21 µm
St. dev.:
11.51
Remarks on result:
other: mean of six measurements
Two test series of three measurements each were performed with the fine fraction of the test item Test series 1:               
 L10 5.10 µm
 L50 28.22 µm     (Median diameter)       
 L90 90.35 µm
Test series 2:
 L10   4.88 µm
 L50 25.27 µm  (Median diameter)
L90 74.07 µm
Average:
L10 4.99 µm 
 L50 26.75 µm      (Median diameter)
 L90 82.21µm 

The additional sieve analysis showed a coarse fraction (agglomerates) of the test item of 16.16 wt.-% with particle sizes > 2000 µm. 5.37 wt.-% of the particles were > 4000 µm.

Conclusions:
The test item Zirconium 2-ethylhexanoate has a median particle size after sieving in the laser apparatus with 2000 µm sieve of L50 = 27 µm, which was determined by laser diffraction measurement.

Description of key information

2-ethylhexanoic acid, zirconium salt has a median particle size after sieving in the laser apparatus with 2000 µm sieve of D50 = 27 µm, which was determined by laser diffraction measurement.
D10 = 4.99 µm
D50 = 26.75 µm
D90 = 82.21 µm

Additional information