EC number: 203-500-9 | CAS number: 107-54-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
General advice:
Seek medical advice. If breathing has stopped or is labored, give assisted respirations. Supplemental oxygen may be indicated. If the heart has stopped, trained personnel should begin cardiopulmonary resuscitation immediately.
Eye contact:
Rinse immediately with plenty of water also under the eyelids for at least 20 minutes. Remove contact lenses.
Skin contact:
Wash off immediately with plenty of water for at least 20 minutes. Wash off with soap and water. Immediately remove contaminated clothing, and any extraneous chemical, if possible to do so without delay.
Ingestion:
Never give anything by mouth to an unconscious person. If a person vomits when lying on his back, place him in the recovery position. Prevent aspiration of vomit. Turn victim's head to the side.
Inhalation:
If breathing has stopped or is labored, give assisted respirations. Supplemental oxygen may be indicated. If the heart has stopped, trained personnel should
begin cardiopulmonary resuscitation immediately. Move to fresh air.
Most important symptoms and effects, both acute and delayed Symptoms:
Repeated and/or prolonged exposure to low concentrations of vapors and/or aerosols may cause: Sore throat.
Fire-fighting measures
Extinguishing media
Suitable extinguishing media:
Alcohol-resistant foam.
Carbon dioxide (CO2).
Dry chemical.
Dry sand.
Limestone powder.
Special hazards arising from the substance or mixture:
Incomplete combustion may form carbon monoxide. Burning produces noxious and toxic fumes. In the event of fire, cool tanks with water spray . Downwind
personnel must be evacuated. Fire or intense heat may cause violent rupture of packages. May form explosive mixtures in air.
Advice for fire-fighters:
Use personal protective equipment. Wear self contained breathing apparatus for fire fighting if necessary.
Accidental release measures
Personal precautions, protective equipment and emergency procedures:
Wear suitable protective clothing, gloves and eye/face protection. Use self-contained breathing apparatus and chemically protective clothing. Remove
all sources of ignition. Evacuate personnel to safe areas.
Environmental precautions:
Construct a dike to prevent spreading. Shut off or remove all ignition sources.
Methods and material for containment and cleaning up:
Contact Air Products' Emergency Response Center for advice. Approach suspected leak areas with caution. Absorb with inert absorbent materials such as:
Dry sand.
Vermiculite.
Activated charcoal.
Place in appropriate chemical waste container.
Additional advice:
Open enclosed spaces to outside atmosphere. If possible, stop flow of product.
Handling and storage
Precautions for safe handling:
Emergency showers and eye wash stations should be readily accessible. Adhere to work practice rules established by government regulations. Use only in well-ventilated areas. Avoid contact with eyes. Avoid breathing vapors and/or aerosols. Use personal protective equipment. When using, do not eat, drink or smoke.
Conditions for safe storage, including any incompatibilities:
Keep containers tightly closed in a dry, cool and well-ventilated place. To avoid ignition of vapors by static electricity discharge, all metal parts of the equipment must be grounded. Keep away from heat and sources of ignition. Keep in a dry, cool place. Keep away from Oxidizers.
Technical measures/Precautions:
Keep away from open flames, hot surfaces and sources of ignition.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Control parameters
If applicable, refer to the extended section of the SDS for further information on CSA.
Exposure controls
Engineering measures:
Maintain process conditions to ensure temperature is below product flashpoint.
Ensure adequate ventilation.
Provide readily accessible eye wash stations and safety showers.
Provide natural or explosion-proof ventilation adequate to ensure concentrations are kept below exposure limits.
Personal protective equipment
Respiratory protection:
Wear appropriate respirator when ventilation is inadequate.
Hand protection:
Neoprene gloves.
Polyvinyl Alcohol Gloves (PVA).
The breakthrough time of the selected glove(s) must be greater than the intended use period.
Eye protection:
Chemical resistant goggles must be worn.
Skin and body protection:
Long sleeve shirts and trousers without cuffs.
Environmental exposure controls:
Construct a dike to prevent spreading. Shut off or remove all ignition sources.
Special instructions for protection and hygiene:
Wash at the end of each workshift and before eating, smoking or using the toilet.
Provide readily accessible eye wash stations and safety showers.
Stability and reactivity
Reactivity:
Refer to possibility of hazardous reactions and/or incompatible materials sections
Chemical Stability:
Stable under normal conditions.
Possibility of hazardous reactions:
No data available.
Conditions to avoid:
Heat, flames and sparks.
Incompatible materials:
Reactive metals (e.g. sodium, calcium, zinc etc.).
Materials reactive with hydroxyl compounds.
Dehydrating Agents.
Oxidizing agents.
Hazardous decomposition products:
Carbon monoxide.
Carbon dioxide (CO2).
Aldehydes
Flammable hydrocarbon fragments.
Heating above 65 C in the presence of strong base can liberate flammable hydrocarbon fragments.
Disposal considerations
Waste treatment methods:
Contact supplier if guidance is required.
Contaminated packaging:
Dispose of container and unused contents in accordance with federal, state, and local requirements.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.