Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
Identification: FAT 40045/Z
Key result
Test procedure:
other: Preliminary study to check if the substacne is flammable
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Safety Pre-Test

A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.

Preliminary screening test

The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes.

Interpretation of results:
GHS criteria not met
Conclusions:
No ignition was observed throughout the course of the test. Hence, the test item FAT 40045/Z should be considered as not highly flammable
Executive summary:

FAT 40045/Z was tested for flammability potential as per guideline EU Method A.10. In a safety pre-test, small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed but the test item did not show any signs of ignition.


Consequently, a screening test was performed. The test item prepared as a 250 mm long pile was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. Hence, the test item FAT 40045/Z TE should be considered as not highly flammable.

Description of key information

FAT 40045/Z was tested for flammability potential as per guideline EU Method A.10. In a safety pre-test, small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed but the test item did not show any signs of ignition. Consequently, a screening test was performed. The test item prepared as a 250 mm long pile was heated with the flame of a teclu burner. Glowing was observed duringheating. No ignition occurred within two minutes. Hence, the test item FAT 40045/Z should be considered as not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

FAT 40045/Z was found o be not flammable in the study conducted as per EU Method A.10. Hence, it does not warrant classification as per the Regulation (EC) No. 1272/2008 (CLP).