Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 400-140-6 | CAS number: 85705-05-1 UGILEC 121
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Emergency measure - Eyes: Rinse immediately with plenty of water
Emergency measure - Skin: Rinse immediately with plenty of water
Emergency measure - Ingestion: Seek medical attention
Fire-fighting measures
Recommended extinguishing agent: Gas evolved in case of fire is essentially CO2 and HCl
fumes. Wear self contained respiratory equipment.
Accidental release measures
Emergency measures in case of spillage: Suck up the liquid with pumps, soak onto absorbent
materials and store in closed containers for ultimate
incineration.
Handling and storage
Handling: Handle as a mildly irritant liquid. Avoid contact with skin
and eyes. Wear protective gloves and goggles.
Storage: No special precautions.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Transport: No special precautions.
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Stability and reactivity
Danger other than fire: None reported
Disposal considerations
Industry - Possibility of recovery/recycling: Condensers: Recover and destroy. Hydraulic fluid: Recover
and regenerate or destroy.
Industry - Possibility of neutralisation: None known
Industry - Possibility of destruction: controlled discharge: Not recommended
Industry - Possibility of destruction - incineration: Almost total destruction (95%) of the substance is achieved
in an incinerator on a fluid bed at 800 deg C for 3
seconds.
Industry - Possibility of destruction - water purification: Sending the substance to a water purification system allows
the production of an effluent almost free of compound and
its concentration in the sludge.
Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.