Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2021-05-11 to 2021-09-17
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Version / remarks:
7th rev. edition, New York and Geneva, 2019
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning rate test: preliminary screening test
Moisture (wt %):
0.48
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

The test item did not ignite at room temperature using a flame as ignition source being applied for at least 2 minutes and 5 minutes, respectively. By applying the flame, the test item glowed for a short time.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The solid test item is neither readily combustible nor flammable.
Executive summary:

In a preliminary test conducted according to UN Test N.1, the test item could not be ignited by a flame within 2 minutes and 5 minutes, respectively. Thus, the performance of the main test was not necessary. The solid test item is neither readily combustible nor flammable.

Description of key information

In a preliminary test conducted according to UN Test N.1, the test item could not be ignited by a flame within 2 minutes and 5 minutes, respectively. Thus, the performance of the main test was not necessary. The solid test item is neither readily combustible nor flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification