Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 Apr 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Qualifier:
according to guideline
Guideline:
DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of 1,10-decanediol dimethacrylate (CAS 6701-13-9) and 10-methacryloyl-oxy-decylphosphate
Molecular formula:
C18H30O4 and C14H27O6P
IUPAC Name:
Reaction mass of 1,10-decanediol dimethacrylate (CAS 6701-13-9) and 10-methacryloyl-oxy-decylphosphate
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Batch number of test material: 5674800
- Purity: 91.8% (sum of two main components)
- Expiration: 22 Jul 2020

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Store in well-ventilated place. Keep container tightly closed. Store locked up.

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
270 °C
Atm. press.:
>= 993.4 - <= 993.6 hPa

Any other information on results incl. tables

 Main test series  Lowest temperatures of an ignition  Highest temperatures without an ignition  Atmospheric Pressure
 1  275 °C  273 °C  992.4 - 1000.2 hPa
 2  272 °C  270 °C  993.4 993.6 hPa
 3  273 °C  270 °C  991.0 - 992.7 hPa

Applicant's summary and conclusion

Conclusions:
The auto ignition of MDP was determined to be 270 °C at 993.4-993.6 hPa (EU Method A.15).
Executive summary:

The auto ignition temperature of MDP was measured according to EU A.15 and DIN 51794. The range of values in three trials was determined to be 272 - 275 °C. The lowest value was rounded down to 270 °C per guideline. The study was conducted under the scope of the the laboratory's ISO/IEC 17025 certification. Therefore, the study is considered reliable without restrictions.