Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 1997-06-06 to 1997-06-30
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Study performed to EU Method with no significant deviations.
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes
Specific details on test material used for the study:
Batch No.: 9705-1A
Purity: >97%
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
negative (not further specified)
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Interpretation of results:
GHS criteria not met
Conclusions:
The test item is not explosive.
Executive summary:

The test item was subjected to thermal and mechanical sensitivity tests to determine its explosive properties according to EU Method A.14 (Explosive properties).

 

In all cases of the thermal sensitivity test, the tubes were recovered unchanged. No evidence of ignition, explosion or decomposition were observed in mechanical sensitivity test.

 

In conclusion, the test item is not explosive.

Description of key information

The test item is not explosive.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

The test item was subjected to thermal and mechanical sensitivity tests to determine its explosive properties according to EU Method A.14 (Explosive properties).

 

In all cases of the thermal sensitivity test, the tubes were recovered unchanged. No evidence of ignition, explosion or decomposition were observed in mechanical sensitivity test.

 

In conclusion, the test item is not explosive.

Justification for classification or non-classification

Explosiveness:

EC A14, Negative results in the thermal and mechanical sensitivity tests.

In accordance with Regulation (EC) No. 1272/2008, figure 2.1.2, the substance shall not be classified as explosive.