Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 November 2007 - 23 February 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
negative (not further specified)
Key result
Test series:
other: European Economy Community (EEC), EEC Directive 92/69 EEC, Part A, Methods for the Determination of Physico-Chemical Properties A14: "Explosive Properties", EEC Publication no. L383, December 29, 1992.
Method:
UN Test 3 (b) (i): BAM friction apparatus
Parameter:
limiting load (N)
Value:
360
Result:
negative, no explosion
Remarks on result:
no mass explosion
Interpretation of results:
GHS criteria not met
Conclusions:
The test substance is not explosive when exposed to intense heat (thermal sensitivity).
The test substance is not explosive when exposed to shock or friction (mechanical sensitivity).

Because no explosion was obtained in any of the thermal or mechanical sensitivity tests, it is concluded that R507-2 presents no danger of explosion.
Executive summary:

The test substance is not explosive when exposed to intense heat (thermal sensitivity).

The test substance is not explosive when exposed to shock or friction (mechanical sensitivity).

 

Because no explosion was obtained in any of the thermal or mechanical sensitivity tests, it is concluded that R507-2 presents no danger of explosion.

Description of key information

The test substance is not explosive when exposed to intense heat (thermal sensitivity).

The test substance is not explosive when exposed to shock or friction (mechanical sensitivity).

 

Because no explosion was obtained in any of the thermal or mechanical sensitivity tests, it is concluded that R507-2 presents no danger of explosion.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

Because no explosion was obtained in any of the thermal or mechanical sensitivity tests, it is concluded that R507-2 presents no danger of explosion. R507 -2 is classified as non explosive.