Administrative data

Description of key information

The substance polymerized to such an extent that it could not be removed by washing on the regenerated human epidermis and therefore could not determine skin corrosiveness. (TG 431)
Testing was impossible because the colouration range required for judgment was outside pH. (TG 435)

Key value for chemical safety assessment

Skin irritation / corrosion

Link to relevant study records
Reference
Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04 September to 30 November 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
Deviations:
no
GLP compliance:
yes
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Maruzen Petrochemical Co. Ltd., 7706RXD
- Expiration date of the lot/batch: no data
- Purity test date: no data

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: The test substance was put into an airtight container under light shielding and stored in a cold place; -30°C to -10°C
- Stability under test conditions: Stable at srorage conditions but will polymerise at room temperature.
- Solubility and stability of the test substance in the solvent/vehicle:
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium:

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing:
- Preliminary purification step (if any):
- Final dilution of a dissolved solid, stock liquid or gel:
- Final preparation of a solid:

FORM AS APPLIED IN THE TEST (if different from that of starting material)

TYPE OF BIOCIDE/PESTICIDE FORMULATION (if applicable)

OTHER SPECIFICS:
Test system:
human skin model
Vehicle:
unchanged (no vehicle)
Details on test system:
RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiDerm SCT (EPI-200)
- Tissue batch number(s): Lot 27112
- Production date: 07 September 2017
- Shipping date:
- Delivery date: 11 September 2017
- Date of initiation of testing: 13 September 2017

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: ambient
- Temperature of post-treatment incubation (if applicable):

REMOVAL OF TEST MATERIAL AND CONTROLS
-Volume and number of washing steps: Rinsed 20 times
- Observable damage in the tissue due to washing:
- Modifications to validated SOP:

MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 5 mg/ml
- Incubation time:
- Spectrophotometer:
- Wavelength:
- Filter:
- Filter bandwidth:
- Linear OD range of spectrophotometer:

FUNCTIONAL MODEL CONDITIONS WITH REFERENCE TO HISTORICAL DATA
- Viability:
- Barrier function:
- Morphology:
- Contamination:
- Reproducibility:

NUMBER OF REPLICATE TISSUES: 2

CONTROL TISSUES USED IN CASE OF MTT DIRECT INTERFERENCE
- Fresh tissues / killed tissues
- Procedure used to prepare the killed tissues (if applicable):
- N. of replicates :
- Method of calculation used:

NUMBER OF INDEPENDENT TEST SEQUENCES / EXPERIMENTS TO DERIVE FINAL PREDICTION:

PREDICTION MODEL / DECISION CRITERIA (choose relevant statement)
- The test substance is considered to be corrosive to skin if [complete, e.g. the viability after 3 minutes exposure is less than 50%, or if the viability after 3 minutes exposure is greater than or equal to 50 % and the viability after 1 hour exposure is less than 15%.]
- The test substance is considered to be non-corrosive to skin if [complete, e.g. the viability after 3 minutes exposure is greater than or equal to 50% and the viability after 1 hour exposure is greater than or equal to 15%.]
- Justification for the selection of the cut-off point(s) if different than recommended in TG 431 and 439:
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 25 mg
- Concentration (if solution):

VEHICLE
- Amount(s) applied (volume or weight with unit):
- Concentration (if solution):
- Lot/batch no. (if required):
- Purity:

NEGATIVE CONTROL
- Amount(s) applied (volume or weight): 50 µL
- Concentration (if solution):

POSITIVE CONTROL
- Amount(s) applied (volume or weight): 50 µL
- Concentration (if solution):
Duration of treatment / exposure:
3min and 60 min
Number of replicates:
2
Irritation / corrosion parameter:
% tissue viability
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
not determinable because of methodological limitations
Interpretation of results:
GHS criteria not met
Conclusions:
The substance polymerized to such an extent that it could not be removed by washing on the regenerated human epidermis and therefore could not determine skin corrosiveness.
Endpoint conclusion
Endpoint conclusion:
no adverse effect observed (not irritating)

Eye irritation

Link to relevant study records
Reference
Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
Deviations:
no
GLP compliance:
yes
Vehicle:
water
Controls:
yes
yes, concurrent vehicle
yes, concurrent positive control
yes, concurrent negative control
Irritation parameter:
cornea opacity score
Run / experiment:
Bovie corneal opacity
Value:
ca. 0
Vehicle controls validity:
valid
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
The substance polymerised during the study.
Interpretation of results:
other: substance polymerised during the study
Conclusions:
Cannot test for eye irritancy since p-vinyl phenol polymerises during the study.
Endpoint conclusion
Endpoint conclusion:
no adverse effect observed (not irritating)

Respiratory irritation

Endpoint conclusion
Endpoint conclusion:
no study available

Additional information

Justification for classification or non-classification

The substance polymerized to such an extent that it could not be removed by washing on the regenerated human epidermis and therefore could not determine skin corrosiveness. (TG 431)
Testing was impossible because the coloration range required for judgment was outside pH. (TG 435)

Therefore it cannot be classified.