Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
4 December 2013 (experimental phase start) to 10 January 2013 (experimental phase end)
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results. The study report was conclusive, done to a valid guideline and the study was conducted under GLP conditions. The study meets the criteria for classification as reliable without restriction according to Klimisch et al (1997).

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
4-(naphthalen-2-yl)-1,3-thiazol-2-amine
EC Number:
606-740-6
Cas Number:
21331-43-1
Molecular formula:
C13H10N2S
IUPAC Name:
4-(naphthalen-2-yl)-1,3-thiazol-2-amine
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
Identification: 4-(2-naphthalenyl)-2-thiazolamine
Description: off white powder
purity 98.8% w/w

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Substances / mixtures which in contact with water emit flammable gases
Remarks on result:
no reaction with water observed
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

Test System

 

The flammability (solids) was determined by measuring the burning rate of test item prepared as a pile of set dimensions. Testing was conducted using a procedure designed to be compatible with Method A10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Principle of the Test

 

The flammability (solids) was determined by measuring the burning rate of the test item.

 

Preliminary screening test

 

A mould (250 mm long x 20 mm wide x 10 mm high) was loosely filled with test item (tested as received). A non-combustible, non-porous board was placed onto the mould which was then inverted. The mould was removed and an air-rich Bunsen burner flame applied to one end of the pile for two minutes.

 

Data Handling

 

If the test item does not ignite and propagate combustion either by burning with a flame or smoldering along 200 mm within 4 minutes, the test item is not considered as highly flammable and no further testing is required.

 

If the test item propagates burning of a 200 mm length in less than 4 minutes, the main test is performed.

 

Result - Preliminary Screening Test

 

The pile failed to ignite during the 2 minutes that the Bunsen flame was applied.

 

The result of the preliminary screening test obviated the need to perform the main test.

The test item has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.

 

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Not highly flammable, using a procedure designed to be compatible with Method A10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.
Executive summary:

Introduction

Hazardous physico-chemical properties of the test item have been determined. Methods employed were designed to be compatible with those specified in Commission Regulation (EC) No 440/2008 of 30 May 2008, Part A: Methods for the determination of physico-chemical properties.

Method

The flammability (solids) was determined by measuring the burning rate of test item prepared as a pile of set dimensions. Testing was conducted using a procedure designed to be compatible with Method A10 Flammability (Solids) ofCommissionRegulation (EC) No 440/2008 of 30 May 2008.

Results Preliminary Screening Test

The pile failed to ignite during the two minutes that the Bunsen flame was applied. The result of the preliminary screening test obviated the need to perform the main test.

Conclusion

The test substance was considered to be not highly flammable.