Administrative data

Endpoint:
oxidising liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because there are no chemical groups present in the molecule which are associated with oxidising properties and hence, the classification procedure does not need to be applied

Data source

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Version / remarks:
Council Regulation 440/2008, 30 May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)

Results and discussion

Applicant's summary and conclusion

Interpretation of results:
other: ← Complete pick list based on CLP criteria, see below
Conclusions:
[DELETE AS APPROPRIATE]
[The test substance in a 1:1 ratio mixture with cellulose spontaneously ignites, under the conditions of the test.]
[The test substance in a 1:1 ratio mixture with cellulose presents a mean pressure rise time ≤ the mean pressure rise time of a 1:1 ratio mixture of [VALUE] % [REFERENCE SUBSTANCE] and cellulose, under the conditions of the test.]
[The test substance in a 1:1 ratio mixture with cellulose does not spontaneously ignite, or exhibit a mean pressure rise, under the conditions of the test.]
Executive summary:

In this guideline (EU A.21) study, [conducted with GLP certification],

[DELETE AS APPROPRIATE]

[The test substance in a 1:1 ratio mixture with cellulose spontaneously ignites]

[The test substance in a 1:1 ratio mixture with cellulose presents a mean pressure rise time ≤ the mean pressure rise time of a 1:1 ratio mixture of [VALUE] % [REFERENCE SUBSTANCE] and cellulose]

[The test substance in a 1:1 ratio mixture with cellulose does not spontaneously ignite, or exhibit a mean pressure rise]

[DELETE AS APPROPRIATE]

[The test substance in a 1:1 ratio mixture with cellulose spntaneously ignites, and is considered an oxidising liquid, category 1, under the criteria of the CLP regulation (1272/2008)]

[The test substance in a 1:1 ratio mixture with cellulose spntaneously exhibits a mean pressure rise time ≤ that of a 1:1 ratio mixture of 50% perchloric acid and cellulose, and is considered an oxidising liquid, category 1, under the criteria of the CLP regulation (1272/2008)]

[The test substance in a 1:1 ratio mixture with cellulose spntaneously exhibits a mean pressure rise time ≤ that of a 1:1 ratio mixture of 40% aqueous sodium chlorate solution and cellulose, and is considered an oxidising liquid, category 2, under the criteria of the CLP regulation (1272/2008)]

[The test substance in a 1:1 ratio mixture with cellulose spntaneously exhibits a mean pressure rise time ≤ that of a 1:1 ratio mixture of 65% aqueous nitric acid and cellulose, and is considered an oxidising liquid, category 3, under the criteria of the CLP regulation (1272/2008)]