Registration Dossier

Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-04-12 - 2017-06-01
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7520 (Particle Size, Fiber Length, and Diameter Distribution)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Key result
Percentile:
D50
Mean:
264 µm
Remarks on result:
other: average of two test series
Percentile:
D10
Mean:
38 µm
Remarks on result:
other: average of two test series
Percentile:
D90
Mean:
672 µm
Remarks on result:
other: average of two test series
Conclusions:
median particle size D50 = 264 µm
Executive summary:

The particle size distribution of the test item 2,4-Diethyl-9H-thioxanthen-9-one was determined by laser light scattering, according to OECD Guideline 110 (and OPPTS 830.7520 and ISO 13320). The test material has a median particle size D50 = 264 µm.

Description of key information

median particle size D50 (determined using OECD 110; GLP): 264 µm

Additional information

The particle size distribution of the test item 2,4-Diethyl-9H-thioxanthen-9-one was determined by laser light scattering, according to OECD Guideline 110 (and OPPTS 830.7520 and ISO 13320).

A reliability score of 1 was assigned, in accordance with the criteria for assigning data quality in line with the principles described by Klimisch (1997).