Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Type of information:
calculation (if not (Q)SAR)
Remarks:
Estimated by calculation
Adequacy of study:
key study
Study period:
1994
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Calculated data
Justification for type of information:
A discussion and report on the read across strategy is given as an attachment in IUCLID Section 13.
Reason / purpose for cross-reference:
read-across: supporting information
Qualifier:
no guideline followed
Principles of method if other than guideline:
Extrapolated from published data
GLP compliance:
no
Remarks:
Estimated by calculation
Conclusions:
The calculated lower and upper flammability range is respectively 0.7 and 6.3 v%.
Executive summary:

The calculated lower and upper flammability range is respectively 0.7 and 6.3 v%.

Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid

Description of key information

There is no data available for Hydrocarbons, C7-C8, isoalkanes, <2% aromatics. However, data is available for structural analogue, Hydrocarbons, C7-C9, isoalkanes, <2% aromaticsand presented in the dossier. This data is read across to based on analogue read across and a discussion and report on the read across strategy is provided as an attachment in IUCLID Section 13.

A study is scientifically unjustified, since hydrocarbons, C7-C9, isoalkanes have a flash point below 23°C and a initial boiling point higher than 35°C and therefore meets the criteria of Category 2 for flammability.

Key value for chemical safety assessment

Flammability:
flammable

Additional information

The upper and lower flammability limit for Hydrocarbons C7-C9, isoalkanes, <2% aromatics was determined by extrapolation from published data as respectively 0.7 and 6.3 v%.

This data is used for read across to Hydrocarbons, C7-C8, isoalkanes, <2% aromatics.

Justification for classification or non-classification

In accordance with REACH Annex XI this study is scientifically unjustified.The flammability of liquids is determined on the basis of their flashpoint (in combination with their boiling point), their ability to emit flammable gases upon contact with water and their pyrophoricity. The molecular structure of Hydrocarbons C7-C9, isoalkanes, <2% aromatics does not contain groups that indicate potential reactivity with water or pyrophoric properties and handling of the substance indicates that this is the case. The flashpoint of Hydrocarbons C7-C9, isoalkanes, <2% aromatics indicates that the substance is a Category 2- Highly flammable liquid. The substance was placed in this hazard class because it has a flash point below 23°C and a initial boiling point higher than 35°C and therefore meets the criteria of Category 2 for flammability.

This data is used for read across to Hydrocarbons, C7-C8, isoalkanes, <2% aromatics.