Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures


After inhalation: fresh air.


 


In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.


 


After eye contact: rinse out with plenty of water. Remove contact lenses.


 


After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.


 


Most important symptoms and effects, both acute and delayed


We have no description of any toxic symptoms.

Fire-fighting measures

Extinguishing media


Suitable extinguishing media: Water, Foam, Carbon dioxide (CO2), Dry powder


 


Unsuitable extinguishing media: For this substance/mixture no limitations of extinguishing agents are given.


 


Special hazards arising from the substance or mixture


Specific hazards during firefighting: Combustible. Development of hazardous combustion gases or vapours possible in the event of fire. Fire may cause evolution of: Hydrogen fluoride


 


Advice for firefighters


Special protective equipment for firefighters: Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.


 


Further information: Suppress (knock down) gases/vapours/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system.

Accidental release measures

Personal precautions, protective equipment and emergency procedures


Advice for non-emergency personnel: Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.


 


Advice for emergency responders: Provide equipment as detailed under "Exposure controls/personal protection".


 


Environmental precautions: Do not flush into surface water or sanitary sewer system.


 


Methods and materials for containment and cleaning up


Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions. Take up dry. Dispose of properly. Clean up affected area. Avoid generation of dusts.

Handling and storage

Precautions for safe handling


Advice on safe handling: Observe label precautions.


 


Hygiene measures: Change contaminated clothing. Wash hands after working with substance.


 


Conditions for safe storage, including any incompatibilities


Storage conditions: Store in original container. Tightly closed. Dry.


 


Recommended storage temperature see product label.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Engineering measures


Technical measures and appropriate working operations should be given priority over the use of personal protective equipment.


 


 


Personal protective equipment


Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled and must meet the specifications of a standard EN/ISO/DIN. The chemical resistance of the protective equipment should be enquired at the respective supplier.


 


Eye/face protection: Safety glasses


 


Hand protection:


- full contact:


      Glove material:       Nitrile rubber


      Glove thickness:       0.11 mm


      Break through time:       > 480 min


- splash contact:


      Glove material:       Nitrile rubber


      Glove thickness:       0.11 mm


      Break through time:       > 480 min


 


The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example: KCL 741 Dermatril® L (full contact); KCL 741 Dermatril® L (splash contact).


 


Respiratory protection: required when dusts are generated.


Recommended Filter type: P1 filter


The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.


 


 


Environmental exposure controls


Do not flush into surface water or sanitary sewer system.

Stability and reactivity

Reactivity


The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.


 


Chemical stability


The product is chemically stable under standard ambient conditions (room temperature).


 


Possibility of hazardous reactions


Violent reactions possible with: Strong oxidizing agents


 


Conditions to avoid: no information available


Materials to avoid: no information available

Disposal considerations

Waste material must be disposed of in accordance with the Directive on waste 2008/98/EC as well as other national and local regulations. Leave chemicals in original containers. No mixing with other waste. Handle uncleaned containers like the product itself.


 


See www.retrologistik.com for processes regarding the return of chemicals and containers.