Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
2009
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
56.58 µm
Geometric standard deviation:
>= 2.36 - <= 2.37
Percentile:
D10
Mean:
>= 7.874 - <= 8.115 µm
St. dev.:
0.087
Key result
Percentile:
D50
Mean:
>= 24.22 - <= 24.962 µm
St. dev.:
0.273
Percentile:
D90
Mean:
>= 69.519 - <= 70.654 µm
St. dev.:
0.746
Conclusions:
Coefficient of variation for d50 is less than 3%, for d10 and d90 less than 3% and thus in the acceptable limits as per ISO 13320-1 test standards
Executive summary:

Mean size is 24.5µm

Description of key information

D50 averages 24.5µm

Additional information