Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
no
Type of method:
pycnometer method
Key result
Type:
relative density
Density:
1.694
Temp.:
20 °C
Conclusions:
Relative density of the test substance, Reactive Violet 1, is 1.694. Uncertainty of determination was estimated to 0.012 (Uncertainty is calculated as 0.886 times the range where 0.886 is a statistical coverage factor for two measured values.).
Executive summary:

The density of the test substance, Reactive Violet 1, was measured. The pycnometer method was used. The procedure was performed according to the Method A.3, Relative density, Council Regulation (EC) No.440/2008, Published in O.J. L 142, 2008.

Relative density of the test substance, Reactive Violet 1, is 1.694. Standard uncertainty is 0.012.

Test temperature was 20 ± 0.1°C.

Description of key information

Key value for chemical safety assessment

Relative density at 20C:
1.694

Additional information