Registration Dossier

Administrative data

Endpoint:
bulk density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2011
Report Date:
2011

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Samples are filled into a flask glass, weighed and tapped. The graduation is then read on the flask.
GLP compliance:
no
Type of method:
other: Bulk density

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder

Results and discussion

Density
Key result
Type:
bulk density
Density:
0.69
Temp.:
20 °C

Applicant's summary and conclusion

Conclusions:
Under the experimental conditions, the bulk density has been measured to be 0.69