Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 September - 07 December 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Study conducted in accordance with international guidelines and in accordance with GLP. All relevant validity criteria were met.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM International, ASTM D7094: “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester”, 2012.
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: United Nations (UN), UN no. ST/SG/AC.10/11/Rev.6: Recommendations on the Transport of Dangerous Goods, Part III: “Non-Viscous Flammable Liquids”, 2015.
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: EraFlash flash-point tester (Eralytics, Vienna, Austria)
Specific details on test material used for the study:
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature
- Stability under test conditions: Assumed stable. Stability at higher temperatures not availbale.
- Solubility and stability of the test substance in the solvent/vehicle: N/A
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: N/A
Key result
Flash point:
104 °C
Atm. press.:
101.325 kPa

Prelim Test

The estimated flash-point of the test substance was 102 ºC.

Main Test

Table 1:       Flash-point of the test substance

Test

Flash-point

[°C]

Lowest flash-point

[°C]

1

104

104

2

104

 

Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method was applied for the determination of the flash-point of the test substance. The flash-point of the test substance was 104 °C.
Executive summary:

The flash-point of the test substance was determined using the closed cup method in accordance with Iso Guide 2719 (2002).

The flash-point of the test substance was determined to be 104 ºC.

 

Description of key information

Flash Point: 104 ºC, ISO Guide 2719 (2002) - closed cup method, Anon, 2017.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
104 °C

Additional information

The flash-point of the test substance was determined using the closed cup method in accordance with Iso Guide 2719 (2002). The flash-point of the test substance was determined to be 104 ºC.

The substance did not meet the classification & labelling criteria for a flammable liquid in accordance with Regulation (EC) No 1272/2008.