Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant, guideline study, available as unpublished report, acceptable without restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
other: N4 (Modified Method) Self Heating Substances
Deviations:
yes
Remarks:
the test item was only available in very limited amounts and was extremely expensive. Therefore, in order to obtain as much information as possible on the self-heating properties of the test item a modified procedure was employed
GLP compliance:
yes (incl. QA statement)
Remarks on result:
no self ignition observed under the test conditions

There were no signs of self-ignition or self heating over the duration of the test.

Conclusions:
Tris(nitrato-O)nitrosylruthenium showed no signs of self-ignition or self-heating over the duration of the test. A negative result was obtained.
Executive summary:

This is a GLP compliant, guideline study considered suitable for use as the key study for this endpoint. Tris(nitrato-O)nitrosylruthenium showed no signs of self-ignition or self-heating over the duration of the test.

Description of key information

Tris(nitrato-O)nitrosylruthenium showed no signs of self-ignition or self-heating over the duration of the test. A negative result was obtained.

Key value for chemical safety assessment

Additional information

Atwal and Tremain (2011) is a GLP compliant study following a modifie N4 method and is considered suitable for use as the key study for this endpoint. Tris(nitrato-O)nitrosylruthenium showed no signs of self-ignition or self-heating over the duration of the test.