Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2006-09-14 to 2006-12-12
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study followed EU Method A.10 and GLP.
Cross-reference
Reason / purpose for cross-reference:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006
Report date:
2006

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Remarks:
The study was conducted according to the guideline in effect at time of study conduct.
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
481-150-8
EC Name:
-
Cas Number:
500011-86-9
Molecular formula:
C9H5BrClN3O2
IUPAC Name:
3-bromo-1-(3-chloropyridin-2-yl)-1H-pyrazole-5-carboxylic acid
Constituent 2
Reference substance name:
DBC80
IUPAC Name:
DBC80
Constituent 3
Reference substance name:
1H-Pyrazole-5-Carboxylic Acid, 3-Bromo-1-(3-Chloro-2-Pyridinyl)-
IUPAC Name:
1H-Pyrazole-5-Carboxylic Acid, 3-Bromo-1-(3-Chloro-2-Pyridinyl)-
Details on test material:
- Name of test material (as cited in study report): IN-DBC80
- Analytical purity: 96.7%
- Lot/batch No.: 008

Results and discussion

Any other information on results incl. tables

The test substance was not found to support combustion in the initial screening test as described above. Since no propagation of the product train occurred within a time specified in the method, there was no need for conducting a full program including six additional burning rate tests to establish a precise burning rate for the test substance.

Applicant's summary and conclusion

Conclusions:
The test substance is not a flammable solid.