Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Principles of method if other than guideline:
The determination of the particle size distribution was carried out by Iaser diffraction according to ISO 13320-1 , with evaluation aeeording to
Fraunhofer
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
bis(N,N,N-trimethyladamantan-1-aminium) sulfate
EC Number:
600-024-7
Cas Number:
1000777-61-6
Molecular formula:
C26 H48 N2 O4 S
IUPAC Name:
bis(N,N,N-trimethyladamantan-1-aminium) sulfate
Test material form:
other: granular
Details on test material:
Name of test material (as cited in study report): Tricyclo[3.3.1.13,7]decan-1-aminium, N,N,N,-trimethyl-, sulfate (2:1)
Analytical purity: 83.2 g/100g (by 1H NMR spectrometry; study no 11 L00496)
Lot/batch No.: ADTAS P5310.10.10
Expiration date of the lot/batch: Oct 20, 2011

Results and discussion

Particle sizeopen allclose all
Percentile:
D10
Mean:
50 µm
Remarks on result:
other: no standard deviation available
Percentile:
D50
Mean:
676 µm
Remarks on result:
other: no standard deviation available
Percentile:
D90
Mean:
1 421 µm
Remarks on result:
other: no standard deviation available
Percentile:
other: D[3.2]
Mean:
124 µm
Remarks on result:
other: no standard deviation available
Percentile:
other: D[4.3]
Mean:
703 µm
Remarks on result:
other: no standard deviation available
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
< 100 µm
Distribution:
16.2 %
No.:
#2
Size:
< 10 µm
Distribution:
1.2 %
No.:
#3
Size:
< 4 µm
Distribution:
0 %

Any other information on results incl. tables

Results in detail:

measurement

d(0.1)

[μm]

d(0.5)

[μm]

d(0.9)

[μm]

D[3,2]

[μm]

D[4,3]

[μm]

1

45.2

644.6

1405.5

115.8

679.2

2

57.4

706.5

1435.4

133.9

726.3

mean*

50

676

1421

124

703

*) Using all single measuring points from the distributions 1 and 2, a new

distribution was calculated, giving the mean values for each parameter.

<100 µm : 16.2 %; <10 µm : 1.2% <4 µm : 0.0%

Applicant's summary and conclusion