Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 20 - August 27, 2010
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Fatty acids C10-20, reaction product with diethylenetriamine
EC Number:
940-308-0
IUPAC Name:
Fatty acids C10-20, reaction product with diethylenetriamine
Test material form:
liquid: viscous
Details on test material:
Test substance: Fatty acids, C10-20 neo, reaction product with diethyelenetriamine
Old names of the test substance: MK195KSF; Naphtenic acids, reaction products with diethylenetriamine
Sample description: orange/brown hazy solid
Storage conditions: at room temperature

Results and discussion

Test results (Oxidising liquids)open allclose all
Sample tested:
test mixture 1:1
Remarks:
Test substance : Cellulose (1:1)
Parameter:
mean pressure rise time
Result:
17.1 s
Remarks on result:
spontaneous ignition does not occur
Sample tested:
reference mixture with 65% nitric acid + cellulose (1:1 ratio)
Parameter:
mean pressure rise time
Result:
4.6 s

Any other information on results incl. tables

  Test substance : Cellulose (1:1)  65% Nitric acid : Cellulose (1:1)
 Test 1 pressure rise time (sec)  20.2 4.4 
 Test 2 pressure rise time (sec)  15.0 5.4 
 Test 3 pressure rise time (sec)  16.4 4.0
 Test 4 pressure rise time (sec)  N/A* 4.6
 Test 5 pressure rise time (sec)  15.2 4.4
 Test 6 pressure rise time (sec)  18.9  N/A
 Mean pressure rise time (sec)  17.1  4.6

* = The coil broke during the test therefore an extra test was conducted (test 6).

The sample of the test substance was found to have a mean pressure rise time greater than that nitric acid reference sample.

The sample is therefore not considered an oxidising liquid.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The substance is not considered an oxidising liquid.