Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
oxidising properties, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13.08.2012-04.09.2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
other: as mention below
Principles of method if other than guideline:
Redox titrations are based on a reduction-oxidation reaction between an oxidizing agent and a reducing agent. A potentiometer or a redox indicator is usually used to determine the endpoint of the titration. In permanganometry a slight faint persisting pink color signals the endpoint of the titration because of the color of the excess oxidizing agent potassium permanganate
GLP compliance:
no
Specific details on test material used for the study:
- Name of test material : Poly(oxy-1,2-ethanediyl),α-hydro-ω-hydroxy- Ethane-1,2-diol, ethoxylated
- Molecular formula : C24H50O13
- Molecular weight : 546.651 g/mol
- Smiles notation : C(COCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCO)O
- Substance type : Organic
- Physical state : Liquid
Key result
Sample tested:
other: not specified (migrated information) ml or mg of KMnO4
Parameter:
other: ml or mg of KMnO4
Result:
91.2 other: ml/100g
Remarks on result:
other: No other detail available
Interpretation of results:
other: no oxidising properties
Conclusions:
Test chemical was not found to have oxidising property.
Executive summary:

Test chemical was not found to have oxidising property.

Endpoint:
oxidising properties, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13.08.2012-04.09.2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
other: as mention below
Principles of method if other than guideline:
Redox titrations are based on a reduction-oxidation reaction between an oxidizing agent and a reducing agent. A potentiometer or a redox indicator is usually used to determine the endpoint of the titration. In permanganometry a slight faint persisting pink color signals the endpoint of the titration because of the color of the excess oxidizing agent potassium permanganate
GLP compliance:
no
Specific details on test material used for the study:
- Name of test material : Poly(oxy-1,2-ethanediyl),α-hydro-ω-hydroxy- Ethane-1,2-diol, ethoxylated
- Molecular formula : C24H50O13
- Molecular weight : 546.651 g/mol
- Smiles notation : C(COCCOCCOCCOCCOCCOCCOCCOCCOCCOCCOCCO)O
- Substance type : Organic
- Physical state : Liquid
Key result
Sample tested:
other: not specified (migrated information) ml or mg of KMnO4
Parameter:
other: ml or mg of KMnO4
Result:
59.1 other: ml/100g
Remarks on result:
other: No other detail available
Interpretation of results:
other: no oxidising properties
Conclusions:
Test chemical was determine to have no oxidising property.
Executive summary:

Test chemical was  determine to have no oxidising property.

Description of key information

Test chemical was not determine to have oxidising property.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Test chemical was not determine to have oxidising property.

Justification for classification or non-classification

Test chemical was not determine to have oxidising property.