Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01/2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Principles of method if other than guideline:
pH measurement in aqueous solution
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)

Test material

Constituent 1
Chemical structure
Reference substance name:
Hydrochloric acid, reaction products with aniline and nitrobenzene, sulfonated, sodium salts
EC Number:
291-454-0
EC Name:
Hydrochloric acid, reaction products with aniline and nitrobenzene, sulfonated, sodium salts
Cas Number:
90411-76-0
Molecular formula:
Mixture of components, no definitve molecular formula existing.
IUPAC Name:
Complex mixture of phenazine dyes - IUPAC name not available
Test material form:
solid: particulate/powder
Details on test material:
- Purity: 80.6 % (according to the sponsor)

Results and discussion

pH valueopen allclose all
pH value:
10.3
Remarks on result:
other: 0.5 g substance in 49.51 g water at room temperature
pH value:
10.4
Remarks on result:
other: 1.0 g substance in 9.01 g water at room temperature

Any other information on results incl. tables

The substance was stirred for 30 min at room temperature with a magnetic stirrer. The concentration ratio was once 1:99 and once 1:9 (substance / water).