Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 January 2010 – 01 April 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study has been performed according to OECD and EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
(6R-trans)-7-amino-3-methyl-8-oxo-5-thia-1-azabicyclo[4.2.0]oct-2-ene-2-carboxylic acid
EC Number:
244-870-1
EC Name:
(6R-trans)-7-amino-3-methyl-8-oxo-5-thia-1-azabicyclo[4.2.0]oct-2-ene-2-carboxylic acid
Cas Number:
22252-43-3
Molecular formula:
C8H10N2O3S
IUPAC Name:
7-amino-3-methyl-8-oxo-5-thia-1-azabicyclo[4.2.0]oct-2-ene-2-carboxylic acid
Details on test material:
- Name of test material (as cited in study report): 7-ADCA
- Molecular formula: C8H10N2O3S
- Molecular weight: 214.2
- Substance type: White powder
- Physical state: solid
- Analytical purity: 99.0%
- Impurities: -
- Isomers composition: -
- Purity test date: -
- Lot/batch No: D212013
- Expiration date of the lot/batch: 28 February 2011 (retest date)
- Stability under test conditions: Stable
- Storage condition of test material: In refrigerator (2-8°C) in the dark
- Other: Test substance handling: -

Results and discussion

Relative self-ignition temperature (solids)
Remarks on result:
other: the test substance is considered ‘not self-ignitable’.

Any other information on results incl. tables

An exothermic effect of the test substance by self-heating was observed at an oven temperature of 195°C. During this effect the test substance reached a temperature of 245°C. According to the guideline, a test substance is self-ignitable when the sample temperature reaches 400°C by self-heating. Based on this, the test substance is considered ‘not self-ignitable’.

 

After the experiment, the test substance had turned into acharred residue and was still in the test cube. It indicated that the test substance had decomposed and/or reacted during the experiment.

Applicant's summary and conclusion

Conclusions:
The self-ignition temperature of 7-ADCA was determined using a temperature programmed laboratory oven, a stainless steel wire mesh cube, NiCr/NiAl thermocouples and a temperature recording device.

Based on the results obtained the test substance is considered ‘not self-ignitable’.