Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Testing was conducted between 30 September 2005 and 26 October 2005.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Sponsor's identification: FSM-005W
Description: white solid
Batch number: 2005-01
Date received: 23 August 2005
Storage conditions: room temperature in the dark under nitrogen over silica gel
The integrity of supplied data relating to the identity, purity and stability of the test material is the responsibility of the Sponsor.
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
22 min
Moisture (wt %):
9.129
Remarks on result:
other: The pile melted then ignited and burnt with an orange flame. Combustion was propagated over the 200 mm in 22 minutes 44 seconds.

The pile melted then ignited and burnt with an orange flame. Combustion was propagated over the 200 mm in 22 minutes 44 seconds.

The results of the preliminary screening test obvaited the need to perform the main test.

Interpretation of results:
GHS criteria not met
Conclusions:
The test material has been determined to be not highly flammable as it did not propagate combustion over the 200 mm of the preliminary screening test in under 4 minutes.
Executive summary:

The test material has been determined to be not highly flammable as it did not propagate combustion over the 200 mm of the preliminary screening test in under 4 minutes, using Method A10 of Commission Directive 92/69/EEC

Description of key information

The test material has been determined to be not highly flammable as it did not propagate combustion over the 200 mm of the preliminary screening test in under 4 minutes, using Method A10 of Commission Directive 92/69/EEC

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The test material has been determined to be not highly flammable as it did not propagate combustion over the 200 mm of the preliminary screening test in under 4 minutes therefore the substance is classified as not flammable.