Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014-10-09 to 2014-10-09
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13736 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
Version / remarks:
2013
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Abel apparatus
Key result
Flash point:
59 °C
Atm. press.:
>= 994.6 - <= 996 hPa

Preliminary test results:

Amount of test item / g

Temperature / °C

Ignition (+/-)*

Air pressure / hPa

68.9

60.2

+

995.1

The lowest temperature where an ignition was observed was 60.2°C.

*) + ("ignition"); - ("no ignition")

Main test results:

In the main test the lowest temperature where an ignition was observed was 58.5 °C.

The average flash point is corrected to the ambient pressure to be 59.26 °C.

The resulting average corrected flash point rounded down to the nearest multiple of 0.5 °C is 59.0 °C.

Amount of test item/ g

Temperature/°C

Ignition(+/-)*

Air pressure/ hPa

Flash point (corr.)/°C

66.15

59.1

+

994.6

59.56

67.83

58.7

+

996.0

59.12

66.83

58.5

+

995.9

58.93

68.13

59.0

+

995.7

59.43

  *) + ("ignition"); - ("no ignition")

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Remarks:
CLP Regulation EC 1272/2008, Annex 1
Conclusions:
The test item has a flash point of 59.0 °C (average corrected and rounded down to the nearest multiple of 0.5°C)
.
Executive summary:

The test item has a flash point of 59.0 °C (average corrected and rounded down to the nearest multiple of 0.5°C) according to Regulation EC No. 440/2008 Method A.9.Flash Point, and DIN EN ISO 13736 (2013) Abel Closed cup test.

According to the results of the test on the flash point, the test item is classified as following:

GHS (CLP Regulation EC 1272/2008 Annex 1: 2.6): With a measured flash point of 59.0°C (>= 23 °C and <=60°C), the test item has to be classified as flammable liquid of category 3 and marked with the warning ‘H226: flammable liquid and vapour ’ according to GHS or CLP Regulation EC 1272/2008 Annex 1.

UN Transport Regulation: The test item has to be classified as flammable liquid of packaging group III.

Description of key information

The test item has a flash point of 59.0°C (average corrected and rounded down to the nearest multiple of 0.5°C) according to Regulation EC No. 440/2008 Method A.9 Flash Point, CIPAC MT 12 (2009) and DIN EN ISO 13736 (2013).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
59 °C

Additional information