Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
(Q)SAR
Adequacy of study:
supporting study
Study period:
27.02.2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
1. SOFTWARE

EPI suite Version 4.11

2. MODEL (incl. version number)

KOWWIN v1.68

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL

(C(C(O)C(O)C1O)CO)C1OC(OC(C(O)C2O)CO)C2O


4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
Documentation of the methods (including literature references) is available within the software tool.

5. APPLICABILITY DOMAIN

Currently there is no universally accepted definition of model domain.  However, users may wish to consider the possibility that log P estimates are less accurate for compounds outside the MW range of the training set compounds, and/or that have more instances of a given fragment than the maximum for all training set compounds.  It is also possible that a compound may have a functional group(s) or other structural features not represented in the training set, and for which no fragment coefficient was developed.  These points should be taken into consideration when interpreting model results.

6. ADEQUACY OF THE RESULT
The prediction is done for the endpoint in question. Therefore the results are treated as adequate.
Qualifier:
no guideline followed
Principles of method if other than guideline:
QSAR calculation using well established software tool
GLP compliance:
no
Type of method:
calculation method (fragments)
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
only in silico calculation
Key result
Type:
log Pow
Partition coefficient:
ca. -5.48
Temp.:
25 °C
Conclusions:
Using Epiwin v. 4.1, the Log Kow is determined to be - 5.48.

Description of key information

one calculation method done,

one experimental study available

For safety assessment, a value of 0 is used.

Key value for chemical safety assessment

Log Kow (Log Pow):
0
at the temperature of:
25 °C

Additional information