Administrative data

Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2021-06-17 to 2021-06-24
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
1-[2-[2-methoxy-4-(morpholin-4-yl)-5-nitroanilino]pyrimidin-4-yl]-3-phenyl-1H-pyrazole-4-carbaldehyde
Cas Number:
1903010-39-8
Molecular formula:
C25H23N7O5
IUPAC Name:
1-[2-[2-methoxy-4-(morpholin-4-yl)-5-nitroanilino]pyrimidin-4-yl]-3-phenyl-1H-pyrazole-4-carbaldehyde
Test material form:
solid: particulate/powder
Details on test material:
- Physical state: solid
- Appearance: orange powder

Results and discussion

Small-scale preliminary testsopen allclose all
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Remarks:
The test item was observed to exhibit no reaction at 40 J.
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N
Remarks:
The test item was observed to exhibit no reaction at 360 N
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not thermal sensitive if heated under defined confinement
Remarks:
The test item did not exhibit an explosion during any of the tests

Any other information on results incl. tables


  1. BAM FALLHAMMER: Test Procedure



The test item was placed in the impact device and the 10 kg weight dropped from a height of 40 cm which is equivalent to 40 J. If an "explosion" was observed, the impact energy was reduced to 7.5 J and further tests conducted.



















Mass (kg)Height (m)Energy (J)Test number and result* (X / ✓)Comments
10 0.4 40 

1 2 3 4 5 6


X X X X X X 


No reaction


* ‘✓’ denotes an explosion (includes crackling, sparking, inflammation).
‘X’ denotes no reaction or decomposition (change in colour).

2. BAM FRICTION: Test procedure

















Mass (kg)Load (N)Test number and result* (X / ✓)Comments
10 360

1 2 3 4 5 6


X X X X X X 


No reaction


* ‘✓’ denotes an explosion (includes crackling, sparking, inflammation).
‘X’ denotes no reaction or decomposition (change in colour).


3. KOENEN TUBE: Test procedure















































Mass of test item (g)Orifice Diameter (mm)Time for First Ignition (s) Explosion (X✓)*
13.0618X
13.0615X
13.0617X
13.0214X
13.0214X
13.0215X

* ‘✓’ denotes 3 or more fragments.
‘X’ denotes fewer than 3 fragments.


 

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
BAM FALLHAMMER: The test item of JNJ-73848255-AAA (T003902) was observed to exhibit no reaction at 40 J. The test result is therefore considered Negative (-) (according to the EC Classification, Packaging & Labelling of Dangerous Substances in the European Union.

BAM FRICTION: The test item of JNJ-73848255-AAA (T003902) was observed to exhibit no reaction at 360 N. The test result is therefore considered Negative (-) (according to the EC Classification, Packaging & Labelling of Dangerous Substances in the European Union.

KOENEN TUBE: The test item did not exhibit an explosion during any of the tests. The test result is therefore considered Negative (-) (according to the EC Classification, Packaging & Labelling of Dangerous Substances in the European Union.