Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 620-400-4 | CAS number: 12031-65-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Cross-reference
- Reason / purpose for cross-reference:
- other: part of a testing strategy
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 021
- Report date:
- 2021
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
- Version / remarks:
- 26 July 2013
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU method B.47 (Bovine corneal opacity and permeability test method for identifying ocular corrosives and severe irritants)
- Version / remarks:
- 09.12.2010
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- Lithium; oxido(oxo)nickel
- Cas Number:
- 12031-65-1
- Molecular formula:
- LiNiO2
- IUPAC Name:
- Lithium; oxido(oxo)nickel
- Test material form:
- solid
Constituent 1
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Batch No. of test material: 8800315
- Content: approx. 99.8 g/100 g
- Homogeneity: the test item appeared to be homogeneous
- Appearance: solid, anthracite
- Expiry Date: 12 August 2021
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: room temperature, under N2
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: The test item (non-surfactant) was tested as suspension in deionised water using sonication for 10 minutes. Before each removal the test item was resuspended.
- Form of application: 20% (w/v) suspention in deionized water
Test animals / tissue source
- Species:
- cattle
- Details on test animals or tissues and environmental conditions:
- SOURCE OF COLLECTED EYES
- Source: Freshly isolated bovine cornea; supplier: AB Schlachthof GmbH & Co. KG, 63739 Aschaffenburg, Germany
- Characteristics of donor animals: age of the animals: 14 month old
- indication of any existing defects or lesions in ocular tissue samples: Corneas free of defects (opacity, scratches, pigmentation etc.)
Test system
- Vehicle:
- water
- Remarks:
- deionized
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 750 µL
- Concentration (if solution): 20% (w/v) solution in de-ionized water
NEGATIVE CONTROL
- Amount(s) applied (volume or weight with unit): 750 µL of de-ionized water
POSITIVE CONTROL
- Amount(s) applied (volume or weight with unit): 750 μL of 20% (w/v) solution of imidazole in deionized wateror - Duration of treatment / exposure:
- 4 hours
- Number of animals or in vitro replicates:
- 3
- Details on study design:
- SELECTION AND PREPARATION OF CORNEAS: Corneas free of defects (opacity, scratches, pigmentation etc.) were dissected with a 2 to 3 mm rim of sclera. Isolated corneas were mounted in cornea holders that consists of anterior and posterior chambers. Both chambers were filled to excess with pre-warmed Eagle’s MEM (without phenol red) and then equilibrated in a vertical position at about 32°C for at least 1 hour. After the equilibration period, the medium in both chambers was replaced by fresh pre-warmed medium and initial corneal opacity readings were taken for each cornea with an opacitometer.
QUALITY CHECK OF THE ISOLATED CORNEAS: Any corneas that showed macroscopic tissue damage or an opacity value < 550 opacity units were discarded. The remaining corneas were then distributed into negative control, positive control and treatment groups.(According to OECD TG 437, corneas that have an opacity value >7 or equivalent for the opacitometer and cornea holders used after an initial one-hour equilibration period are to be discarded. In the test facility´s opacitometer in combination with the used cornea holder set 2013-22 and 2013-24, the maximal initial opacity of >7 arises from I= 550 lux with Io= 641 lux).
NUMBER OF REPLICATES: 3
NEGATIVE CONTROL USED: Yes
POSITIVE CONTROL USED: Yes
APPLICATION DOSE AND EXPOSURE TIME: Application of 750 µL of the 20% (w/v) test-substance preparation, 4 hours exposure time
REMOVAL OF TEST SUBSTANCE
- Number of washing steps after exposure period: at least 3 times.
- POST-EXPOSURE INCUBATION: no
METHODS FOR MEASURED ENDPOINTS:
- Corneal opacity: Yes.
- Corneal permeability: passage of sodium fluorescein dye measured with the aid of microtiter plate reader: Yes, OD490, OP_KiT opacitometer (Electro Design, 63-Riom France).
SCORING SYSTEM: In Vitro Irritancy Score (IVIS)
DECISION CRITERIA:
IVIS ≤ 3, Prediction: No Category
IVIS > 3; ≤ 55, Prediction: No prediction can be made
IVIS > 55, Prediction: Category 1
Results and discussion
In vitro
Results
- Irritation parameter:
- in vitro irritation score
- Remarks:
- IVIS
- Run / experiment:
- Run 1, mean of three single corneas
- Value:
- 355.13
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- other: Cathegory 1, serious eye damage
- Other effects / acceptance of results:
- OTHER EFFECTS:
- Visible damage on test system: No.
DEMONSTRATION OF TECHNICAL PROFICIENCY: Proficiency given
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: yes
- Acceptance criteria met for positive control: yes
Any other information on results incl. tables
Table 1: Results of the BCOP Test, in vitro irritancy score (IVIS) of the test substance, the NC and the PC.
Opacity value per cornea | Permeability at 490 nm (OD490) | IVIS | |||
substance identification | per cornea | per group | |||
mean | SD | ||||
400.00* | 0.889* | 413.34 | |||
Test substance | 326.00* | 1.201* | 344.02 | 355.13 | 53.52 |
291.00* | 1.136* | 308.04 | |||
0 | 0.066 | 0.99 | |||
NC (Saline) | 0 | 0.078 | 1.17 | 1.08 | 0.09 |
0 | 0.072 | 1.08 | |||
** | ** | ** | |||
NC (deionised water) | 2.00 | 0.078* | 2.00 | 1.00 | 1.41 |
0.00 | 0.061* | 0.00 | |||
81.00* | 0.605* | 90.08 | |||
PC (10% (w/v) Benzalkonium chloride in saline) | 68.00* | 0.471* | 75.07 | 80.11 | 8.63 |
67.00* | 0.545* | 75.18 | |||
88.00* | 0.771* | 99.57 | |||
PC (20 % Imidazole in saline) | 97.00* | 1.239* | 115.59 | 97.04 | 19.93 |
65.00* | 0.731* | 75.97 |
*Correction was performed with the values of the Negative Control Saline.
** not taken into the evaluation since this value is declared as an outlier.
Applicant's summary and conclusion
- Interpretation of results:
- Category 1 (irreversible effects on the eye) based on GHS criteria
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.