Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Short-term toxicity to aquatic invertebrates

Administrative data

Endpoint:
short-term toxicity to aquatic invertebrates
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1995
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: according to GLP and according to guideline but tested above solubility and vehicle was used. Not clear if test substance caused adverse effects or the undissolved particles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1995
Report date:
1995

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method C.2 (Acute Toxicity for Daphnia)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Triphenyl phosphite
EC Number:
202-908-4
EC Name:
Triphenyl phosphite
Cas Number:
101-02-0
Molecular formula:
C18H15O3P
IUPAC Name:
triphenyl phosphite
Details on test material:
- Physical state: liquid
- Storage condition of test material: room temperature

Sampling and analysis

Analytical monitoring:
yes
Details on sampling:
Composite samples of each test concentration were drawn by mixing identical volumes of the test solutions taken from the approximate center of the test vessels. They were taken immediately before exposure and after 48 hours exposure and kept at - 18°C to-22"C until analysis.

Test solutions

Vehicle:
yes
Details on test solutions:
PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)

- Concentration of vehicle in test medium (stock solution and final test solution): 50.9 mg test substance and 2 ml of a TWEEN 80 solution in water (0.1% w/w) were mixed by polytron for 5 minutes and made up to 500 ml with water.

Calculated amounts of the stock solution to produce the desired test concentrations and vehicle to achieve identical vehicle concentrations were given into the
water and were homogeneously distributed. After an equilibration time of 24 hours, the daphnia were transferred into the beakers.

- Evidence of undissolved material (e.g. precipitate, surface film, etc):
The test concentration 10 mg/l was visibly above the limit of solubility. Inspite this fact the test substance was homogeneously distributed in the test vessels at all test times and test concentrations.

Test organisms

Test organisms (species):
Daphnia magna
Details on test organisms:
TEST ORGANISM
- Strain: Straus 1820
- Source: Ciba-Geigy Ltd testing facility
- Age at study initiation (mean and range, SD): 0-24h (separated 24h before begin of exposure)
- Length at study initiation (length definition, mean, range and SD): 800 microm
- Method of breeding: Cultures of daphnia are maintained in glass vessels containing approx. 2.5 1 of reconstituted water (see below) at 20 ± 1 °C (water is renewed partially thrice weekly). At each renewal the daphnia are fed with a suspension of green algae (Scenedesmus subspicatus) supplemented by a suspension of TETRAMIN-extract in such quantities that the food is consumed after 24h.


Pre-treatment:
24 hours before the begin of the exposure reproductive daphnia are separated from the young by sieving all individuals through a 800 |.im sieve.
This operation is repeated immediately before the exposure and the young (0-24h of age) are retained for the test.


Study design

Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
48 h

Test conditions

Test temperature:
20-23°C
pH:
8-8.1
Dissolved oxygen:
measured at: 0, 48h
99-100%
Nominal and measured concentrations:
nominal: 0.58,1.0,1.8, 3.2, 5.8 and 10 mg test substance/l
measured (start of exposure)0.50, 0.86,1.58, 2.75, 5.12 and 8.54 mg/l
measured (end of exposure): 0.43, 0.74,1.39, 2.51,4.57 and 8.08 mg/l
measured (mean): 0.47, 0.80,1.49, 2.63, 4.85, 8.31 mg test substance /I
blank: water
vehicle: 0.4 mg polyoxy-ethylene-sorbitan-monooleate (TWEEN80)
Details on test conditions:
TEST SYSTEM
- Test vessel: beakers covered with watch glasses
- Fill volume: 100mL
- Aeration: none


TEST MEDIUM / WATER PARAMETERS
reconstituted water containing
65 mg NaHCO3
294 mg CaCl2 x 2 H2O
123 mg MgSO4 x 7 H2O
6 mg KCl
in 1000 ml bidistilled water.
Total hardness: 240 mg CaCOa/l
The water was aerated with clean air for at least 24 hours before use.


- Intervals of water quality measurement: The oxygen content, pH and temperature were measured at 0 and 48 hours.

OTHER TEST CONDITIONS
- Photoperiod: Fluorescent light, 16 hours daily approx. 1500 lux


EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
Immobilizations were recorded after 24 and 48 hours exposure

TEST CONCENTRATIONS
- Results used to determine the conditions for the definitive study: Pretests showed that the EC 50 will be between 0.58 and 10 mg/I.

Results and discussion

Effect concentrationsopen allclose all
Key result
Duration:
48 h
Dose descriptor:
EC50
Effect conc.:
0.94 mg/L
Nominal / measured:
meas. (arithm. mean)
Basis for effect:
mobility
Remarks on result:
other: calculated and graphically determined
Duration:
24 h
Dose descriptor:
EC50
Effect conc.:
16.5 mg/L
Nominal / measured:
meas. (arithm. mean)
Basis for effect:
mobility
Remarks on result:
other: calculated
Duration:
48 h
Dose descriptor:
EC100
Effect conc.:
> 8.31 mg/L
Nominal / measured:
meas. (arithm. mean)
Basis for effect:
mobility
Remarks on result:
other: observed
Duration:
48 h
Dose descriptor:
EC0
Effect conc.:
< 0.47 mg/L
Nominal / measured:
meas. (arithm. mean)
Basis for effect:
mobility
Remarks on result:
other: observed
Duration:
48 h
Dose descriptor:
NOEC
Effect conc.:
< 0.48 mg/L
Nominal / measured:
meas. (arithm. mean)
Basis for effect:
mobility
Remarks on result:
other: observed
Details on results:
The test concentration 10 mg/l was visibly above the limit of solubility. Inspite this fact the test substance was homogeneously distributed in the test vessels at all test times and test concentrations.

The actual test concentrations were within 80± 20% of the nominal concentrations, therefore following values were calculated based on actual mean
concentrations: 0.47, 0.80,1.49, 2.63, 4.85 and 8.31 mg/l.

The EC-50 values were calculated according to BERKSON,JASA 48 (1953), 569- 599. EC-values were graphically determined on gausso-Iogarithmic paper

Applicant's summary and conclusion