Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

General: remove the victims from the danger area; seek immediate medical assistance; show the specific MSDS to the physicians; treat simptomatically. Wear protective equipment for eyes, skin, hands; wear self contained respiratory protection. Do not allow presence of unprotected people in the area.
If inhaled: remove the victim to fresh air and keep at rest in a position confortable for breathing. If breathing difficulties persist due to accidental inhalation of dust, vapours, aerosols or combustion fumes, provide oxygen and/or artificial respiration. Seek immediate medical assistance.
If in eyes: rinse cautiously and thoroughly with plenty of water. Remove contact lenses, if present and easy to do; continue rinsing. If eyes irritation persist, get medical advice.
If on skin and clothes: remove contaminated clothing and shoes. Wash thoroughly with soap and water. Wash clothing before re-use.
If ingested: contact immediately a POISON CENTER or a doctor. Rinse repeatedly the mouth with water without swallowing. Do not induce vomiting or administer anything without medical advice.

Fire-fighting measures

Extinguishing media: water spray or fog; foam; dry chemical powder; CO2; dry sand.
Specific hazards arising from the substance: dangerous combustion products: Carbon oxides; Nitrogen oxides.
Protective device for fire-fighting people: protective device/clothing for head, hands, skin and eyes. Self-contained respiratory apparatus.
Fire-fighting water/media must be disposed as hazardous wastes in compliance with current Regulations. persist, get medical advice.

Accidental release measures

General: do not allow unprotected people in the area; send away those who are not in charge to manage the issue. Use PPE as adequate for eyes, skin and breathing apparatus. Prevent contact with ignition sources.
Environmental: prevent dispersed material to reach sewers and water courses.
Methods for cleaning up: use inert absorbents (sand, kieselgur,,,); collect mechanically the released material and dispose according to waste handling procedures, Ventilate the area, if proper; if necessary wash with water disposing the resulting liquid as hazardous waste.

Handling and storage

General: the substance is stable in normal storage conditions, however, as a precautionary measure, store in a fresh, dry and well ventilated area. Use local exhaust during charging/discharging and when collecting samples. Only protected, informed people should handle the substance.
Emissions: captured air and process emissions should be properly handled before immission in atmosphere (gaseous emissions purification system).
Waste: waste deriving from activities involving the substance should be considered hazardous and handled as such.
Storage Store in well closed, leakproof containers in well ventilated, dedicated area. Prevent/protect from contact with electrostatic charges or other ignition sources. Avoid moisture, light exposition and proximity with incompatible materials (strong acid and bases, oxidants).
Further measures: as additional protection measure, workers should wear proper PPE for skin (overalls), hands (gloves), eyes (googles) and self-contained respiratory device when handling the substance. Strictly follow directions for use, cleaning and maintenance reported by the supplier for each kind of PPE. Wash accurately before re-use.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

The substance is handled in SCC. Refer to attached filke for details. Personnel in charge for handling (sampling, charge into reaction vessels etc.) should wear proper disposable protection clothing, gloves, respiratory protection device (mask or self-contained apparatus), googles.
Periodical controls of personnel exposure to the substance are in place according to specific SOPs.

Stability and reactivity

Stable under normal conditions of use.
Conditions to avoid: very high temperatures could origin decomposition with emission of toxic/irritating/corrosive fumes.
Thermal decomposition could result in emission of oxides of Carbon and Nitrogen.
Materials to avoid: acid and bases; oxidizing agents.

Disposal considerations

Strictly observe all local, regional, national and international environmental Regulations. Wastes deriving from handling/using the substance should be considered as hazardous and disposed as such. Containers should be handled in the same way.
Disposal of waste: keep in well closed containers and send waste (including contaminated containers) to authorized companies for disposal,