Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25-Sep-2013 to 13-Nov-2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
GLP compliance:
no
Type of method:
distillation method
Key result
Boiling pt.:
210.2 °C
Atm. press.:
1 020 hPa
Decomposition:
no
Remarks:
not observed below 210 °C

Results

Boiling point of [test item] at 101.4 kPa

 

 

Temperature

Sample name

Item

°C

K

[test item]

Boiling point

210.2

483.4

Note: Temperature in Kelvin (K) = Temperature in °C + 273.15 

 

Boiling point results under atmospheric pressure (102.0 kPa)

 

 

Temperature

Sample name

Item

Run

°C

K

[test item]

Boiling point

1

210.3

483.5

2

210.1

483.3

Average

210.2

483.4

Note: Temperature in Kelvin (K) = Temperature in °C + 273.15 

 

Conclusions

The boiling point was measured using a general distillation apparatus under atmospheric pressure. Conclusively, the boiling point of [test item] was 210.2 °C (483.4 K) at 102.0 kPa. Reaction and/or decomposition of the test material was not observed below 210.2 °C (483.4 K).

Conclusions:
A boiling point of 210.2 °C (at 1020 hPa) was determined for the test substance according to OECD 103.

Description of key information

Boiling point: 210.2 °C at 1020 hPa (EU Method A.2, distillation method)

Key value for chemical safety assessment

Additional information