Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
4 October 2010 to 13 December 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP complaint, guideline study, available as unpublished report acceptable without restrictions
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Version / remarks:
Screening Test
Principles of method if other than guideline:
The method used is based on a procedure designed to comply with that given in 'Particle size distribution, fibre length and diameter distribution', June 1996 European Commission technical guidance document, which satifies the requirements of OECD Guideline 110
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
No.:
#1
Size:
< 100 µm
Distribution:
16.2 %

The results of the sieving procedure are shown below:

 Measurement

Result 

Mass of test item transferred to sieve 

10.13g

 Mass of test item passed through sieve

1.64g

Proportion of test item <100µm 

16.2%
Conclusions:
In an OECD 110 Granulometry (Screening Test) the proportion of Tetraamminepalladium (2+) dichloride <100 μm was 16.2 %
Executive summary:

This is a GLP compliant, guideline study considered suitable for use as the key study for this endpoint. The proportion of Tetraamminepalladium (2+) dichloride < 100 μm is 16.2 %

Description of key information

The proportion of tetraamminepalladium (2+) dichloride <100 μm was 16.2 %.

Additional information

Atwal and Tremain (2011) is a GLP compliant, guideline study considered suitable for use as the key study for this endpoint. The proportion of tetraamminepalladium (2+) dichloride < 100 μm is 16.2 %.

The dustiness of tetraamminepalladium(2+) dichloride was tested in a modified Heubach procedure according to the guideline DIN 55992-1:2006 (Selck and Parr 2011). The study is non-GLP, but follows a standard guideline and is considered to be reliable. The total dustiness of tetraamminepalladium(2+) dichloride was determined to be 99.93 mg/g. The inhalable fraction was 61.67 mg/g, the thoracic fraction was 11.96 mg/g and the respirable fraction was 1.40 mg/g. The Mass Median Aerodynamic Diameter (MMAD) was 25.72 μm with Geometric Standard Deviation of 1.91 μm.