Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted following ASTM D93 -Procedure A
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
Procedure A
Deviations:
no
GLP compliance:
no
Remarks:
conducted under good manufacturing practices (GMP)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks on result:
no flash point up to 100°C
Remarks:
A small distinct flash was noted at at 105°C. Continued to heat up to 110°C the flame was extinguished with no flash
Conclusions:
Not able to determined flash point using ASTM D93 Procedure A. No flash point up to 100°C. A small distinct flash was noted at 105°C, however after continued to heat up to 110°C the flame was extinguished with no flash.

Description of key information

Not able to determined flash point using ASTM D93 Procedure A. No flash point up to 100°C. A small distinct flash was noted at 105°C, however after continued to heat up to 110°C the flame was extinguished with no flash.

Key value for chemical safety assessment

Additional information