Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 204-482-5 | CAS number: 121-57-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Skin sensitisation
Administrative data
- Endpoint:
- skin sensitisation: in vivo (LLNA)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Study according to OECD test guideline 429 under GLP
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 010
- Report date:
- 2010
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 429 (Skin Sensitisation: Local Lymph Node Assay)
- Deviations:
- yes
- Remarks:
- relative humidity out of range without any impact on study
- GLP compliance:
- yes (incl. QA statement)
- Type of study:
- mouse local lymph node assay (LLNA)
Test material
- Reference substance name:
- Sulphanilic acid
- EC Number:
- 204-482-5
- EC Name:
- Sulphanilic acid
- Cas Number:
- 121-57-3
- Molecular formula:
- C6H7NO3S
- IUPAC Name:
- 4-aminobenzene-1-sulfonic acid
- Details on test material:
- Identity:Sulfanilic Acid (sieved)
Batch No.:M 002/10
Purity:98.5%
Storage:At room temperature, moisture protected
Expiration Date:May 01, 2012
Constituent 1
In vivo test system
Test animals
- Species:
- mouse
- Strain:
- CBA
- Sex:
- female
- Details on test animals and environmental conditions:
- TEST ANIMALS
- Source: Harlan Laboratories B.V., Postbus 6174, 5960 AD Horst / The Netherlands
- Age at study initiation: 8-12 weeks
- Weight at study initiation: 17.8 -22.1 g
- Housing: single caging (Makrolon Type II, with wire mesh top) with granulated soft wood bedding
- Diet (e.g. ad libitum): ad libitum
- Water (e.g. ad libitum): ad libitum
- Acclimation period: at least 5 days
ENVIRONMENTAL CONDITIONS
- Temperature (°C): 22 + 2°C
- Humidity (%): 39-81 %
- Air changes (per hr): -
- Photoperiod (hrs dark / hrs light): 12/12
Study design: in vivo (LLNA)
- Vehicle:
- propylene glycol
- Concentration:
- 5, 10, 25%
- No. of animals per dose:
- 4
- Details on study design:
- MAIN STUDY
ANIMAL ASSIGNMENT AND TREATMENT
- Name of test method: LLNA
- Criteria used to consider a positive response:
A test item is regarded as a sensitiser in the LLNA if the following criteria are fulfilled:
- First, that exposure to at least one concentration of the test item resulted in an incorporation of 3HTdR at least 3-fold or greater than that recorded in control mice, as indicated by the stimulation index.
- Second, that the data are compatible with a conventional dose response, although allowance must be made (especially at high topical concentrations) for either local toxicity or immunological suppression.
TREATMENT PREPARATION AND ADMINISTRATION:
Each test group of mice was treated by topical (epidermal) application to the dorsal surface of each ear (left and right) with different test item concentrations of 5, 10, and 25% (w/w) in propylene glycol. The application volume, 25 µl, was spread over the entire dorsal surface (0 - 8 mm) of each ear once daily for three consecutive days. A further group of mice was treated with an equivalent volume of the relevant vehicle alone (control animals). - Positive control substance(s):
- hexyl cinnamic aldehyde (CAS No 101-86-0)
Results and discussion
- Positive control results:
- The sensitivity and reliability of the experimental technique employed was assessed by use of a-hexyl cinnamaldehyde dissolved in acetone:olive oil (4:1 v/v) (compound listed in OECD 429 Guideline) which is known to have skin sensitisation properties in mice, CBA/CaOlaHsd. The validation- / positive control experiment was performed with a-Hexylcinnamaldehyde in acetone:olive oil (4+1) using CBA/CaOlaHsd mice in May 2010,
In vivo (LLNA)
Resultsopen allclose all
- Parameter:
- SI
- Remarks on result:
- other: 5%: 0.84 10%: 0.98 25%: 0.79
- Parameter:
- other: disintegrations per minute (DPM)
- Remarks on result:
- other: negative control group: 2495 5%: 2101 10%: 2453 25%: 1966
Applicant's summary and conclusion
- Interpretation of results:
- not sensitising
- Remarks:
- Migrated information
- Conclusions:
- in a study according to OECD test guideline 429 under GLP, the test substance was determined to be not skin sensitising.
- Executive summary:
In the study (acc. to OECD test guideline 429) the test substance suspended in propylene glycol was assessed for its possible contact allergenic potential. For this purpose a local lymph node assay was performed using test item concentrations of 5, 10, and 25%. The animals did not show any clinical signs during the course of the study and no cases of mortality were observed. A test item is regarded as a sensitiser in the LLNA if the exposure to one or more test concentration resulted in 3-fold or greater increase in incorporation of 3HTdR compared with concurrent controls, as indicated by the Stimulation Index (S.I.). The estimated concentration of test item required to produce a S.I. of 3 is referred to as the EC3 value. In this study Stimulation Indices (S.I.) of 0.84, 0.98, and 0.79 were determined with the test item at concentrations of 5, 10, and 25% in propylene glycol, respectively. The test substance was not a skin sensitiser in this assay.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.