Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Test phase 2014-01-30 to 2014-02-25. Report date 2014-04-15.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Meets the criteria for classification as Reliable without restriction according to Klimisch et al (1997).

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
lithium hydrogen 7-{(E)-[2-amino-4-(2-naphthyl)-1,3-thiazol-5-yl]diazenyl}naphthalene-1,3,5-trisulfonate (2:1:1)
EC Number:
940-433-0
Molecular formula:
C23H14Li2N4O9S4
IUPAC Name:
lithium hydrogen 7-{(E)-[2-amino-4-(2-naphthyl)-1,3-thiazol-5-yl]diazenyl}naphthalene-1,3,5-trisulfonate (2:1:1)
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: The pile failed to ignite during the 2 minutes that the Bunsen flame was applied in the preliminary screening test.

Any other information on results incl. tables

Preliminary screening test

The pile failed to ignite during the 2 minutes that the Bunsen flame was applied. The result of the preliminary screening test obviated the need to perform the main test.

Applicant's summary and conclusion

Interpretation of results:
other: not highly flammable
Conclusions:
The test item has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.
Executive summary:

Introduction

The flammability (solids) was determined by measuring the burning rate of test item prepared as a pile of set dimensions. Testing was conducted using a procedure designed to be compatible with Method A10 Flammability (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Results & Conclusion

The pile failed to ignite during the 2 minutes that the Bunsen flame was applied. The result of the preliminary screening test obviated the need to perform the main test. The test item has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.