Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
2-ethyl-2-propyl-1,3,6,2-trioxasilocane; 4-(3-aminopropyl)-4-ethoxy-3,5,8-trioxa-4-siladecan-10-ol; 7-(3-aminopropyl)-7-ethoxy-3,6,8,11-tetraoxa-7-silatridecane-1,13-diol
EC Number:
688-124-7
Cas Number:
152261-43-3
Molecular formula:
unspecified
IUPAC Name:
2-ethyl-2-propyl-1,3,6,2-trioxasilocane; 4-(3-aminopropyl)-4-ethoxy-3,5,8-trioxa-4-siladecan-10-ol; 7-(3-aminopropyl)-7-ethoxy-3,6,8,11-tetraoxa-7-silatridecane-1,13-diol
Test material form:
liquid: viscous

Results and discussion

Test results (Oxidising liquids)open allclose all
Key result
Sample tested:
test mixture (not specified)
Parameter:
mean pressure rise time
Result:
10 661.7 ms
Remarks on result:
spontaneous ignition does not occur
Key result
Sample tested:
reference mixture with 65% nitric acid + cellulose (1:1 ratio)
Remarks:
migrated information
Parameter:
mean pressure rise time
Result:
3 488 ms
Remarks on result:
spontaneous ignition does not occur

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
The test item can not be classified as an oxidising substance.
Executive summary: