EC number: 479-090-2 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
- General advice: Remove contaminated clothing and shoes. Ensure that the First Aid Personnel are aware of the product involved, and take precautions to protect themselves (e.g. wear personal protection equipment).
- Following inhalation: Remove to fresh air.
- Following skin contact: Remove contaminated clothes. Wash with soap and water. If irritation occurs, seek medical advice.
- Following eye contact: Flush eyes with water at least 15 minutes. Get medical attention if eye irritation develops or persists
- Following ingestion: If swallowed, call a poison control centre or doctor immediately. Treat symptomatically.
- Most important symptoms and effects: No effects expected. In case of symptoms appear seek medical advice.
Fire-fighting measures
- Suitable extinguishing media: Water, dry powder, foam, carbon dioxide.
- Unsuitable extinguishing media: No restrictions.
- Special hazards arising from the substance or mixture: In case of fire hazardous decomposition products may be produced such as Carbon oxides (CO, CO2), Nitrogen oxides (NOx), Sulphur oxides (SOx).
- Advice for fire fighter:
Use Self-contained breathing apparatus and full protective suit. Cool endangered containers with water spray jet. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations. Do not disperse powdered product in air.
Accidental release measures
- Personal precautions: Ensure adequate ventilation. Wear suitable protective equipment. Keep away sources of ignition.
- Protective equipment and emergency procedures: Wear suitable protective equipment such as a dust mask , chemical protective gloves and eye protection.
- Environmental precautions: Collect contaminated fire extinguishing water separately. This must not be discharged into drains. The product should not be allowed to enter drains, water courses or the soil.
- Methods and material for containment and cleaning up: Sweep up (wet powders with water) and place in suitable containers for disposal. After processing, clean all equipment with water. Rinse with water.
Handling and storage
- Precautions for safe handling:
Keep container tightly closed.
Observe usual precautions when handling chemicals.
If the pure substance is handled as powder, avoid inhalation of dust and wear dust mask.
Use equipment for handling powders or other appropriate engineering controls.
Avoid eye and skin contact and wear safety goggles and impermeable gloves.
Keep away from sources of ignition - No smoking.
Take measures to prevent the build up of electrostatic charge.
Avoid dust formation.
Observe the usual precautionary measures required for chemicals with dust explosive properties (Observe national regulations).
- Conditions for safe storage, including any incompatibilities:
The substance should be stored in well sealed and secure containers in adequate rooms, at room temperature.
Handle and open container with care.
Keep away sources of ignition.
Avoid residues outside the containers.
Keep only in the original container.
Do not store or transport together with foodstuffs,
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Transport code: Not classified.
Transport: Transport in well sealed suitable containers (eg.
polyethylene sacks in steel drums). The containers should be
secured against falling down. Label containers in
accordance with pertinent regulations.
SpecialProvisionsopen allclose all
Exposure controls / personal protection
1. Technical protection measures: Local ventilation recommended - mechanical ventilation may be used.
2. Organisational protection measures: Observe the usual precautions for handling chemicals. Ensure that eyewash stations and safety showers are close to the workstation location. Avoid contact with skin and eyes.
3. Hand protection: Chemical resistant gloves
4. Feet protection: Wear suitable protective equipment.
5. Body protection: Wear suitable protective equipment.
6. Eye protection: Depending on the risk, wear sufficient eye protection (safety glasses with side protection or goggles, and if necessary, face shield.)
7. Respiratory protection: Local ventilation to keep levels below established threshold values is recommended. In case of prolonged exposure to airborne dust concentrations, a suitable particle filter mask that complies with the requirements of national legislation is recommended, depending on the expected exposure levels.
Stability and reactivity
1. Reactivity: Acid dye.
2. Chemical stability: Stable under normal conditions.
3. Possibility of hazardous reactions: Risk of dust explosion.
4. Conditions to avoid: Keep away from heat. Keep away from open flames, hot surfaces and sources of ignition.
5. Incompatible materials: not known.
6. Hazardous decomposition products: When handled and stored appropriately, no dangerous decomposition products are known
Disposal considerations
Possibility of recovery/recycling: Under normal processing the substance will be chemically bound to fibres to 99.99%.
No method for the recycling or recovery of the remaining substance is available.
Not suitable for deposit in landfill site.
Incineration in an approved, controlled furnace with combustion gas scrubbing and
emission gas control.
Removal by controlled discharge to a waste water treatment plant: It is estimated that approx. 0.01% of the total quantity used is discharged into internal industrial effluents as highly diluted solution. A purification of the waste water in a waste water treatment plant is recommended. The
dyestuff should be used in a well equiped dye house.
If necessary, the waste water can be purified prior to the waste water treatment by membrane filtration or by floculation with appropriate agents or by treatment with ozone. The most effective method is the membrane filtration: more than 99% of the remaining dyestuff can be removed from the waste water.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.