Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 18 July 2007 and 29 August 2007.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
cascade impaction
Type of distribution:
mass based distribution

Test material

Constituent 1
Reference substance name:
Magenta T-43
IUPAC Name:
Magenta T-43
Test material form:
solid: particulate/powder
Details on test material:
Sponsor's identification: MAGENTA T-43
Description: dark red solid
Storage conditions: room temperature, in the dark
Lot number: H186-5

Results and discussion

Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
100 µm
Distribution:
60.5 %
Remarks on result:
other: Proportion of test material having an inhalable particle size, sieve method
No.:
#2
Size:
10 µm
Distribution:
1.77 %
Remarks on result:
other: Proportion of test material having a thoracic particle size, cascade impactor method
No.:
#3
Size:
5.5 µm
Distribution:
0.21 %
Remarks on result:
other: Proportion of test material having a respirable particle, cascade impactor method

Any other information on results incl. tables

Results

 

Definitive test (cascade impactor method)

 

The results of the cascade impactor method were tabulated. 

 

Cascade Impactor: Determination 1

 

Cup Number

Particle Size Range Collected (µM)

Cup Masses (g)

Pre-Sampling

Post-Sampling

Difference

1

>10.0

86.1398

89.1390

2.9992

2

5.5-10.0

85.4742

85.5283

0.0541

3

2.4-5.5

85.8849

85.8896

0.0047

4

1.61-2.4

85.6339

85.6346

0.0007

5

0.307-1.61

85.7772

85.7774

0.0002

Filter

<0.307

75.1904

75.1916

0.0012

 

 

Amount of test material found in artificial throat: 0.03 g.

 

Total amount of test material recovered from impactor cups, filter and artificial throat: 3.0901 g.

The cumulative amounts found for the individual particle size cut-points (µm) were tabulated.

 

Particle size cut-points: Determination 1

 

Cup number

Particle Size Cut-Points (µm)

Cumulative Mass of Test Material (g)

Cumulative Amount of Test Material (%)

2

10.0

0.0609

1.97

3

5.5

0.0068

0.220

4

2.4

0.0021

6.80 x 10-2

5

1.61

0.0014

4.53 x 10-2

Filter

0.307

0.0012

3.88 x 10-2

  

 

 Cascade Impactor: Determination 2

 

The results of the cascade impactor method were tabulated. 

 

Cup Number

Particle Size Range Collected (µM)

Cup Masses (g)

Pre-Sampling

Post-Sampling

Difference

1

>10.0

86.1400

89.1299

2.9899

2

5.5-10.0

85.4741

85.5111

0.0370

3

2.4-5.5

85.8848

85.8884

0.0036

4

1.61-2.4

85.6339

85.6351

0.0012

5

0.307-1.61

85.7770

85.7774

0.0004

Filter

<0.307

75.1877

75.1881

0.0004

 

Amount of test material found in artificial throat: 0.01 g.

 

Total amount of test material recovered from impactor cups, filter and artificial throat: 3.0425 g.

The cumulative amounts found for the individual particle size cut-points (µm) were tabulated.

 

Particle size cut-points: Determination 2

 

Cup number

Particle Size Cut-Points (µm)

Cumulative Mass of Test Material (g)

Cumulative Amount of Test Material (%)

2

10.0

0.0426

1.40

3

5.5

0.0056

0.184

4

2.4

0.0020

6.57 x 10-2

5

1.61

0.0008

2.63 x 10-2

Filter

0.307

0.0004

1.32 x 10-2

 

 

 

Cascade Impactor: Determination 3

 

The results of the cascade impactor method were tabulated. 

 

Cup Number

Particle Size Range Collected (µM)

Cup Masses (g)

Pre-Sampling

Post-Sampling

Differencei

1

>10.0

86.1408

89.1298

2.9890

2

5.5-10.0

85.4746

85.5273

0.0527

3

2.4-5.5

85.8854

85.8893

0.0039

4

1.61-2.4

85.6339

85.6346

0.0007

5

0.307-1.61

85.7775

85.7776

0.0001

Filter

<0.307

75.1845

75.1867

0.0022

 

Amount of test material found in artificial throat: 0.01 g.

 

Total amount of test material recovered from impactor cups, filter and artificial throat: 3.0586 g.

The cumulative amounts found for the individual particle size cut-points (µm) were tabulated.

 

Particle size cut-points: Determination 3

 

Cup number

Particle Size Cut-Points (µm)

Cumulative Mass of Test Material (g)

Cumulative Amount of Test Material (%)

2

10.0

0.0596

1.95

3

5.5

0.0069

0.226

4

2.4

0.0030

9.81 x 10-2

5

1.61

0.0023

7.52 x 10-2

Filter

0.307

0.0022

7.19 x 10-2

 

The overall cumulative amounts of test material with a particle size less than 10.0 µm (%)from Determinations 1 to 3 were tabulated.

 

Determination

Cumulative Amount of Test Material Less Than 10.0 µm (%)

Mean Cumulative Amount of Test Material Less Than 10.0 µm (%)

1

1.97

1.77

2

1.40

3

1.95

 

 

The overall cumulative amounts of test material with a particle size less than 5.5 µm (%) from Determinations 1 to 3 were tabulated.

 

Determination

Cumulative Amount of Test Material Less Than 5.5 µm (%)

Mean Cumulative Amount of Test Material Less Than 5.5 µm (%)

1

0.220

 

0.210

2

0.184

3

0.226

 

Concluding Particle Size Data

Measurement

Method

Result

Proportion of test material having an inhalable particle size < 100µm

Sieve

60.5%

Proportion of test material having a thoracic particle size < 10.0 µrn

Cascade Impactor

1.77%

Proportion of test material having a respirable particle size < 5.5 µm

Cascade Impactor

0.210%

Applicant's summary and conclusion

Conclusions:
The proportion of test material having an inhalable particle size less than 100 µm = 60.5% by the sieve method.
The proportion of test material having a thoracic particle size less than 10 µm = 1.77% by the cascade impactor method.
The proportion of test material having a respirable particle size less than 5.5 µm = 0.210% by the cascade impactor method.

Mass Median Diameter: Too few particles were of a size less than 10 µm to allow accurate assessment of mass median aerodynamic diameter.
Executive summary:

The particle size distribution of substance Magenta T-43 was determined to have 60.5% inhalable particle size < 100 µm by the sieve method; 1.77 % thoracic particle size < 10 µm by the cascade impactor method and 0.210% respirable particle size < 5.5 µm by the cascade impactor method, according to the OECD Test Guideline 110.