Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-01-18 to 2018-02-12
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
agglomerate
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
>= 38 - <= 81 µm
Percentile:
D50
Mean:
>= 38 - <= 81 µm
Remarks on result:
other: Standard deviation not reported
Percentile:
D10
Mean:
>= 10 - <= 12 µm
Remarks on result:
other: Standard deviation not reported
Percentile:
D90
Mean:
>= 203 - <= 240 µm
Remarks on result:
other: Standard deviation not reported

The test item consisted of irregular formed particles which had a very strong tendency for agglomeration. The particles had a sticky behavior and seemed to be electrostatically charged after sieving. These effects obstructed a measurement via sieve analysis and influenced the results of the study using laser diffraction. A large part of the test item was present as agglomerates with a diameter above 1 mm. Hence, the test item was sieved with a mesh size of 1000 µm. Only 23% (w/w) of the test item passed the sieve and only this fraction was measured by laser diffraction. A significant part of the coarse fraction consisted of fine particles that agglomerated and blocked the sieve due to the sticky behaviour of the sample.

Median particle size D (v, 0.5): 50% of particle volume or particle mass with lower particle diameter

1st measurement: 73 µm

2nd measurement: 38 µm

3rd measurement: 81 µm

Measured range: 38 - 81 µm

Particle size D (v, 0.1): 10% of particle volume or particle mass with lower particle diameter

1st measurement: 12 µm

2nd measurement: 10 µm

3rd measurement: 12 µm

Measured range: 10 - 12 µm

Particle size D (v, 0.9): 90% of particle volume or particle mass with lower particle diameter

1st measurement: 243 µm

2nd measurement: 203 µm

3rd measurement: 240 µm

Measured range: 203 - 240 µm

The particle size distribution showed a polymodal distribution. Four maxima were observed. These maxima were at approximately 2 µm, 20 µm, 100 µm and 1000 µm. The third and fourth maximum presented most likely

agglomerates. The three measurements differed in the fractions of the different particle sizes. This was a result of the behaviour of the sample.

Conclusions:
The particle size distribution of the test item was determined by laser diffraction (light scattering):
Range of median particle size D (v, 0.5): 38 - 81 µm
Range of particle size D (v, 0.1): 10 - 12 µm
Range of particle size D (v, 0.9): 203 - 240 µm
Executive summary:

The particle size distribution of the test item was determined by laser diffraction (light scattering). A large part of the test item was present as agglomerates with a diameter above 1 mm. Hence, the test item was sieved with a mesh size of 1000 µm. Only 23% (w/w) of the test item passed the sieve and only this fraction was measured by laser diffraction.

Range of median particle size D (v, 0.5): 38 - 81 µm

Range of particle size D (v, 0.1): 10 - 12 µm

Range of particle size D (v, 0.9): 203 - 240 µm

Description of key information

The particle size distribution of the test item was determined by laser diffraction (light scattering). A large part of the test item was present as agglomerates with a diameter above 1 mm. Hence, the test item was sieved with a mesh size of 1000 µm. Only 23% (w/w) of the test item passed the sieve and only this fraction was measured by laser diffraction.

Range of median particle size D (v, 0.5): 38 - 81 µm

Range of particle size D (v, 0.1): 10 - 12 µm

Range of particle size D (v, 0.9): 203 - 240 µm

Additional information