Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 23 to 24 November 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
The study was conducted according to an internationally recognised method, and under GLP. The substance is considered to be adequately characterised. Therefore full validation applies.
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Version / remarks:
2008
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)
Remarks:
GLP compliance programme (inspected on 20-21 June 2017 / signed on 4 September 2017)
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
< -20 °C
Decomposition:
no

Results

Melting point / melting range : Differential scanning calorimetry

Two DSC measurements in aluminium crucibles with a hole with addition of glass pearls were performed. In each case the test item was cooled down to -50 °C with a cooling rate of 1 K/min, kept at ‑50 °C for 30 min and afterwards the test item was heated up to 500 °C with a heating rate of 10 K/min. No effect was observed during the cooling phase and keeping the test item at -50 °C. During the heating phase an exothermal effect was observed starting at 180 °C, directly followed by an endothermal effect.

Graphical presentations of the DSC runs are shown on page 7 of the experimental report. No event was observed when the test item was cooled down to -50°C.

Under consideration of the result from the DSC measurement it was concluded that the test item had no freezing/melting point until -20 °C.


Conclusions:
The freezing point of test item was stated as < - 20 °C (< 253.15 K).
Executive summary:

The freezing point of the test item was determined under GLP according to EU Method A.1 and OECD 102.

 

In a DSC test, no effect was observed during the cooling phase and keeping the test item at -50 °C. According to Regulation (EC) No 1907/2006 (REACH) annex VII, column 2 of section 7.2, the determination of the melting / freezing point does not need to be conducted below a lower limit of - 20 °C. Therefore, no additional test was conducted and the freezing point is stated as < - 20 °C (< 253.15 K).

Description of key information

The freezing point is stated as: < - 20 °C (< 253.15 K).

Key value for chemical safety assessment

Additional information

A fully reliable experimental study, conducted according to a recognized OECD/EC method and under GLP, is available. It is considered as a key study.

In a DSC test, no effect was observed during the cooling phase and keeping the test item at -50 °C. According to Regulation (EC) No 1907/2006 (REACH) annex VII, column 2 of section 7.2, the determination of the melting / freezing point does not need to be conducted below a lower limit of - 20 °C.