Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
disregarded due to major methodological deficiencies
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
23-03-2006
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
static method

Test material

Constituent 1
Chemical structure
Reference substance name:
Oxo(propan-2-olato)aluminium
EC Number:
270-365-0
EC Name:
Oxo(propan-2-olato)aluminium
Cas Number:
68425-65-0
Molecular formula:
C3 H7 Al O2
IUPAC Name:
oxo(propan-2-olato)aluminium
Test material form:
solid: particulate/powder

Results and discussion

Vapour pressure
Key result
Remarks on result:
not determinable
Remarks:
The sample could not be analyzed by the static method because it is the fine powder which contaminates valves and seals of the instrument.

Applicant's summary and conclusion

Conclusions:
The sample could not be analyzed by the static method because it is the fine powder which contaminates valves and seals of the instrument.