Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
other: ASTM D 6450
Deviations:
not specified
GLP compliance:
not specified
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
other: Not specified
Key result
Flash point:
> 100 °C
Atm. press.:
101.3 kPa
Remarks on result:
no flash point - measurement carried out until boiling temperature
Interpretation of results:
other: CLP criteria not met
Conclusions:
Under the study conditions, the boiling point of the test substance was determined to be >100°C at 101.3 kPa(boiling point).
Executive summary:

A study was conducted to determine the flash point of the test substance, according to Guideline ASTM D 6450. During the study there is no flash point was determined till boiling point. Under the study conditions, the flash point of the test substance was determined to be >100°C at 101.3 kPa (boiling point) (Dobbelstein, 2018).

Description of key information

The flash point was determined according to ASTM Guideline D6450 (Dobbelstein, 2018).

Key value for chemical safety assessment

Additional information

The flash point was determined to be >100°C at 1013 hPa.