Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental starting date: 23 February 2017; Experimental completion date: 05 May 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Disodium 3,3'-[carbonylbis[imino(3-methoxy-4,1-phenylene)azo]]bis[benzenesulphonate]
EC Number:
233-316-4
EC Name:
Disodium 3,3'-[carbonylbis[imino(3-methoxy-4,1-phenylene)azo]]bis[benzenesulphonate]
Cas Number:
10114-86-0
Molecular formula:
C27H22N6Na2O9S2
IUPAC Name:
disodium 3,3'-[carbonylbis[imino(3-methoxy-4,1-phenylene)azo]]bis[benzenesulphonate]
Test material form:
solid: particulate/powder
Details on test material:
Identification: CIM-42(Direct Yellow 132)
Appearance/physical state: dark orange colored powder
Batch: 161011K
Purity: 94.0%
Expiry / Retest date: 01 December 2017
Storage conditions: Room temperature, in the dark over silica

Results and discussion

Small-scale preliminary testsopen allclose all
Parameter:
other: BAM friction test
Remarks on result:
negative (not further specified)
Parameter:
other: BAM Fall Hammer Test
Remarks on result:
negative (not further specified)
Parameter:
other: Koenen Steel Tube Test
Remarks on result:
negative (not further specified)

Any other information on results incl. tables

BAM Friction Test:

Results of the BAM Friction test are shown in the following table:

Test

Observations

1

There were no signs of sparks or ignition. A dark mark on the porcelain plate and peg indicated decomposition.

2

There were no signs of sparks or ignition. A dark mark on the porcelain plate and peg indicated decomposition.

3

There were no signs of sparks or ignition. A dark mark on the porcelain plate and peg indicated decomposition.

4

There were no signs of sparks or ignition. A dark mark on the porcelain plate and peg indicated decomposition.

5

There were no signs of sparks or ignition. A dark mark on the porcelain plate and peg indicated decomposition.

6

There were no signs of sparks or ignition. A dark mark on the porcelain plate and peg indicated decomposition.

Result: Negative

BAM Fall Hammer Test

Results of the BAM Fall Hammer test are shown in the following table:

Test

Observations

1

There were no signs of explosion, flames or fumes emitted. When the test assembly was dismantled there were no signs of decomposition.

2

There were no signs of explosion, flames or fumes emitted. When the test assembly was dismantled there were no signs of decomposition.

3

There were no signs of explosion, flames or fumes emitted. When the test assembly was dismantled there were no signs of decomposition.

4

There were no signs of explosion, flames or fumes emitted. When the test assembly was dismantled there were no signs of decomposition.

5

There were no signs of explosion, flames or fumes emitted. When the test assembly was dismantled there were no signs of decomposition.

6

There were no signs of explosion, flames or fumes emitted. When the test assembly was dismantled there were no signs of decomposition.

Result: Negative

 Koenen Steel Tube Test

Results of the Koenen Steel Tube test are shown in the following tables

Koenen Steel Tube Test - 6 mm Orifice Plate

Test

Time (s)

Observations

1

53

A yellow flame emitted from the orifice.

147

A ‘pop’ sound heard.

192

Test item slowly being ejected from the orifice.

300

The test was stopped.

The tube was recovered intact.

2

58

A yellow flame emitted from the orifice.

184

A ‘pop’ sound heard.

225

Test item slowly being ejected from the orifice.

300

The test was stopped.

The tube was recovered intact.

3

57

A yellow flame emitted from the orifice.

190

A ‘pop’ sound heard.

236

Test item slowly being ejected from the orifice.

300

The test was stopped.

The tube was recovered intact.

Koenen Steel Tube Test - 2 mm Orifice Plate

Test

Time (s)

Observations

1

52

A yellow flame emitted from the orifice.

185

A ‘pop’ sound heard.

234

Test item slowly being ejected from the orifice.

300

The test was stopped.

The tube was recovered intact.

2

55

A yellow flame emitted from the orifice.

164

A ‘pop’ sound heard.

210

Test item slowly being ejected from the orifice.

300

The test was stopped.

The tube was recovered intact.

3

52

A yellow flame emitted from the orifice.

202

A ‘pop’ sound heard.

231

Test item slowly being ejected from the orifice.

300

The test was stopped.

The tube was recovered intact.

Result: Negative

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item has been determined to not have explosive properties.
Executive summary:

Explosive Properties. Non-explosive, using a procedure designed to be compatible with Method A.14 Explosive Properties of Commission Regulation (EC) No 440/2008 of 30 May 2008.