Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study performed under GLP. All relevant validity criteria were met.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Deviations:
no
Qualifier:
equivalent or similar to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected January 2013; signature: March 2013
Type of method:
equilibrium method closed cup
Flash point:
149.5 °C
Atm. press.:
ca. 1 013.1 hPa
Remarks on result:
other: Determination completed at atmospheric pressure (1013.0 - 1013.1 hPa range)

Table1: Preliminary test

Amount of test item / g

Temperature / °C

Ignition (+/-)

Air pressure / hPa

67.47

150.0

+

1019.5

In the preliminary test the lowest temperature where an ignition was observed was 150.0 °C.

 

Main Test

The results of the main test are summarized in the following table. The result “ignition” is indicated by + and “no ignition” by - sign.

Table2: Main test

Amount of test item / g

Temperature /
°C

Ignition /
(+/-)

Air pressure / hPa

Corrected flash point / °C

65.79

150.0

+

1013.1

150.0

66.51

150.0

+

1013.0

150.0

The measured flash points are corrected to the ambient pressure and averaged to be 150.0 °C.

The resulting average corrected flash point rounded down to the nearest multiple of 0.5 °C is 149.5 °C

Conclusions:
The flash point of the test substance has been determined to be 149.5 °C at 1013.1 hPa atmospheric pressure.
Executive summary:

The flash point was determined using EU Method A.9 closed cup equilibrium method. In the main test the lowest temperature where an ignition was observed was 150.0 °C at 1013.1 hPa, which was then corrected to the ambient pressure to be 150.0 °C. The resulting corrected flash point rounded down to the nearest multiple of 0.5 °C is 149.5 °C. The flash point of the substance has been determined to be 149.5 °C at 1013.1 hPa atmospheric pressure.

Description of key information

FP: 149.50 °C at 1013.1 hPa atmospheric pressure, EU Method A.9, 2016

Key value for chemical safety assessment

Additional information

The flash point was determined using EU Method A.9 closed cup equilibrium method. In the main test the lowest temperature where an ignition was observed was 150.0 °C at 1013.1 hPa, which was then corrected to the ambient pressure to be 150.0 °C. The resulting corrected flash point rounded down to the nearest multiple of 0.5 °C is 149.5 °C. The flash point of the substance has been determined to be 149.5 °C at 1013.1 hPa atmospheric pressure.