Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
5 November 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
Name: FAT 36091
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
GHS criteria not met
Conclusions:
No ignition was observed throughout the course of the test. The test item FAT 36091/I TE should be considered as not highly flammable.
Executive summary:

The flammability of the test item was evaluated in a study conducted according to EU Method A.10. In this study, the test item was formed into an unbroken strip or powder train about 250 mm long. The pile was arranged at right angle to the draught in the fume cupboard. The flame of the gas burner was used to ignite the pile at one end. A stop watch was held ready. No ignition was observed throughout the course of the test. Hence, the test item FAT 36091/I TE should be considered as not highly flammable.

Description of key information

The flammability of the test item was evaluated in a study conducted according to EU Method A.10. In this study, the test item was formed into an unbroken strip or powder train about 250 mm long. The pile was arranged at right angle to the draught in the fume cupboard. The flame of the gas burner was used to ignite the pile at one end. A stop watch was held ready. No ignition was observed throughout the course of the test. Hence, the test item FAT 36091/I TE should be considered as not highly flammable.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification