Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Screening test; GLP - Acceptable, well documented publication/study report which meets basic scientific principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report date:
1999

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Principles of method if other than guideline:
Preliminary test: The flammability (solids) was determined by measuring the burning rate of the test material prepared as a pile of dimensions. Testing was based on the Method A10 of the Commission directive 92/69/EEC (which constitutes Annex V of the Council directive 67/548/EEC).
GLP compliance:
yes (incl. QA statement)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Sponsors identification: ARAKAWA KE-604
Description: pale yellow blocks
Batch No.: R61132
Purity: no data

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

The pile of test material ignited and burnt with an orange flame which self extinguished 3 seconds after the bunsen burner was removed, failing to propagate combustion. The result of the preliminary test obviated the need to perform the main test for flammability.

Applicant's summary and conclusion

Executive summary:

Arakawa KE-604 has been determined to be not highly flammable as it did not propagate combustion over the 200 mm of the preliminary screeening test. The result of the preliminary screening test obliviated the need to perform the main flammability test.